The BITZER REFRIGERANT RULER enables easy and fast determination of refrigerant data. The app contains all common refrigerants, including key fluid properties, safety group information, global warming potential (GWP), ozone depletion potential (ODP), and information on choice of oil type for the compressor. Furthermore, additional information on refrigerants, links to relevant online documents and other information are displayed (under "More..." in the menu bar). The tool provides an intuitive user interface for easy and accurate temperature-to-pressure conversion, while allowing easy use and switching between different metric (SI) and imperial (IP) units (under "Settings").
// CURRENTLY AVAILABLE REFRIGERANTS //
▸ The app contains data and information on more than 100 natural and synthetic refrigerants, which can also be preselected by filter functions (under "Search").
▸ For comparison purposes and also for practical use in service and operation of older existing systems, information on previously used refrigerants, which may have been affected by usage restrictions, are also provided.
// MAIN FUNCTIONS //
▸ Search filters and favourites: Under the navigation item "Search" or via predetermined "Search filters" or manual entry in the text field the appropriate refrigerant can be found and, if necessary, added to the favourites by tapping the "star symbol". With a simple touch on the selected refrigerant, the slider for the pressure-temperature conversion is displayed.
▸ Ruler: By means of a slider, the values of pressure, dew and boiling (bubble) temperatures (temperature glide resulting from the difference) for the selected refrigerant can be determined. Pressure and temperature values can also be entered manually - either by tapping on the respective field or via the symbol "123". When installing the app overpressure values are preset. With this setting, the atmospheric pressure can be entered either manually on the upper ruler or via the "barometer symbol" to correct the pressure values. A change to absolute pressure values is possible under "Settings", the atmospheric pressure correction is then inactive. Further function: By tapping on the refrigerant name, direct access to "Search" (refrigerant list and search filters) is also possible.
▸ Settings: Under this menu all important parameters for the determination of the atmospheric pressure as well as for temperature and pressure values can be adjusted. Other functions allow for a change to default settings and a repeated display of the “Tutorials” in the ruler view.
▸ Automatic Barometer: The app offers the possibility to determine the current altitude above sea level and/or the actual atmospheric pressure to correct the corresponding dew and bubble temperatures in case of overpressure settings. Depending on the configuration, the analysis for the location in question is optionally carried out automatically via GPS or barometer if the corresponding terminal has the aforementioned sensors. Manually entering the atmospheric pressure or correction is possible as described under “Slider control”.
▸ Temperature / pressure: Temperature and pressure units can be freely selected and combined, if necessary, a mix of SI and IP units is possible as well. For overpressure (or negative pressure) bar (g) or psig / inHg can be selected. In the Setting psig / inHg displays the overpressure values in "psig" and the negative pressure values in "negative inHg" (e.g., -7.5 inHg).
▸ Further information on refrigerants: General and additional information can be found under the information symbol "i" in the header next to the refrigerant name. These include, for example, GWP and ODP values for the refrigerants, safety group, chemical composition or components in mixtures, CAS number, molecular weight, triple and boiling (bubble) points, critical temperature, critical pressure and information on the type of oil for the compressor.
What’s New
Version 3.4.0
• Additional explanations on the detail page of a refrigerant
• Atmospheric pressure can now be picked in kilopascals (kPa)
• Simplified search and navigation
• Updated refrigerant data
• New data set: R472A and R472B
• Performance- and stability improvements
Ratings and Reviews
Fehler
Manche Kältemittel funktionieren nach dem Update nicht mehr richtig. Bitte beheben, ansonst eine tolle App
aktuell
keine Funktion, wenn man App in den Store verschiebt, kann man sie auch nicht mehr löschen!? Hoffe das ist temporär. Sonst ist die App sehr gut
App Privacy
The developer, BITZER SE, indicated that the app’s privacy practices may include handling of data as described below. For more information, see the developer’s privacy policy.
Data Not Linked to You
The following data may be collected but it is not linked to your identity:
- Location
- Usage Data
- Diagnostics
Privacy practices may vary based on, for example, the features you use or your age. Learn More
Information
- Provider
- BITZER SE
- Size
- 21.8 MB
- Category
- Reference
- Compatibility
-
- iPhone
- Requires iOS 13.0 or later.
- iPod touch
- Requires iOS 13.0 or later.
- Mac
- Requires macOS 11.0 or later and a Mac with Apple M1 chip or later.
- Apple Vision
- Requires visionOS 1.0 or later.
- Languages
-
English, German
- Age Rating
- 4+
- Copyright
- © 2022 BITZER Kuehlmaschinenbau GmbH
- Price
- Free