Protractors, well-sharped pencils, are obsolete for measuring patients X-Rays! This app is not a simple goniometer or ruler, is an enhanced product !!

CE angle is one of the most frequently applied anatomic measures for the evaluation and description of the geometry of the hip in everyday orthopedic care. Measurements of CE angle in X-rays are valuable because you can determine and monitor objectively the severity of dysplasia, and establish the need for surgery and follow up the treatment.
Wiberg’s or center edge (CE) angle is formed at the juncture of the Perkin line with line drawn from the center of the femoral head to the outer edge of the acetabular roof. The center edge angle may distinguish between acetabular insufficiency, under coverage or overcoverage of the femoral head by the acetabulum.
Measurements of CE angle in X-rays is important during the decision-making process for conservative or operative treatment, and follow up particular, in Developmental Dysplasia of the hip, or planning correction-osteotomies. Measuring angles in X-rays in clinical settings it is time consuming. Accessory instruments like protractors, goniometers, well sharped pencils, rulers must be available in a busy everyday practice. Usually you miss or you never had one or another. Also after measurement you have to compare the data that you measure with the normal reference values according to patient age and decide what could be considered normal in an X-ray of the hip and what is considered pathologic.
Center-Edge Angle app is a medical software aimed for orthopaedic surgeons, providing tools that allow doctors to: Securely import medical images directly from the camera or stored photos. Offers a very convenient way to determine the most accurate possibly lines in order to measure the angles. By the aid of a circular transparent template, the points of interest are marked accurately. The automatically formed lines, drawn between points, measure automatically the angles of interest.
All information received from the software output must be clinically reviewed regarding its plausibility before patient treatment! CE App is indicated for assisting healthcare professionals. Clinical judgment and experience are required to properly use the software. The software is not for primary image interpretation.
The app is a handy tool for an orthopaedic surgeon, radiologist, medical student or resident who wants objectively to monitor and determine the severity of dysplasia of the hip. The build-in comparison feature with the normal reference values according to patient age may help decide what could be considered normal or dysplastic or pincer (FAI). The app is not a simple goniometer, is an enhanced product which offers the ability to compare all the input data with medical reference database. The results are printed on the screen and the hips are categorized as normal or dysplastic or severe dysplastic or pincer (FAI) according to the angle measured. This feature it is particular useful especially in clinical settings where you need a quick results without losing time in looking for reference data according to age variations in huge textbook. The circular template to determine the points of interest and to mark them accurately are very useful in clinical settings where finding a sharpened pencil, a protractor and manage to draw with ruler lines over the patients x-rays is definitely a cumbersome and tedious task. You can load from your photo library or capture a photo from x-rays of the patient in you mobile phone or tablet, the App simply guides you to do the rest.
Reference
1.Wiberg G. The anatomy and roentgenographic appearance of a nor mal hip joint. Acta Chir Scand. 1939;83:7-38
2.Philippon MJ, Wolff AB, Briggs KK, Zehms CT, Kuppersmith DA. Acetabular rim reduction for the treatment of femoroacetabular impingement correlates with preoperative and postoperative center- edge angle. Arthroscopy. 2010;26:757-761.
3.James et al Relationship Between the Lateral Center-Edge Angle and 3-Dimensional Acetabular CoverageOrthop J Sports Med. 2017 Apr; 5(4): Published online 2017 Apr 12.

App Privacy

The developer, ORTHOPRACTIS.COM SINGLE MEMBER P.C., indicated that the app’s privacy practices may include handling of data as described below. For more information, see the developer’s privacy policy.

Data Not Collected

The developer does not collect any data from this app.

Privacy practices may vary based on, for example, the features you use or your age. Learn More

Supports

  • Family Sharing

    Up to six family members can use this app with Family Sharing enabled.

More By This Developer

PotsiApp
Medical
OsteotomyApp
Medical
SonoHipAngles
Medical
HipNaviPro
Medical
Dynamic3DFaceAsymmetryApp
Medical
WhereMyCup
Medical

You Might Also Like

Orthopedic Classification
Medical
Orthopedic Clinical Signs Lite
Medical
CTisus: CT of the Hand & Wrist
Medical
Orthopedic Limbs Anatomy
Medical
Loa Movement
Health & Fitness
Maxx Ortho
Medical