Odrid HMI 4+

Jan Almqvist

    • 6,99 €

Beschreibung

Operator panel for various industrial control system. Communication over Wi-Fi or mobile internet with the protocols Modbus/TCP (Class 0 and 1), Modbus RTU class 1 and Siemens S7 Communication (ISO-on-TCP).

Odrid HMI is an alternative to traditional SCADA systems and operator panels. The app supports multiple data types and has easy navigation between pages.

Odrid HMI is also great to use for home automation with PLCs that have eg Modbus/TCP protocol is implemented to remotely control and monitor lighting, ventilation, heating etc in the residence or holiday home.

Advantages:

Excellent technical support.
Free updates.
Graphic HMIs with multi touch function can be created in minutes.
Free-of-charge development tool with test run feature.
Virtually unlimited number of pages, objects and variables.
Does not require any third-party services.
Genuine native app, not based on neither HTML nor OPC technology.

Features:

Parameters for communication such as IP address, port number, protocol, etc. can be specified per page.
Automatic polling of all variables displayed in the current page, no need for separate tag list.
Many formats for numeric variables such as 16 and 32 bit integer, unsigned, hex, ASCII, float (IEEE 754), etc.
Prioritized event-driven transfer to the controller.
Pages are edited in the measurement unit dp (Density Independent Pixels).
Life bit for monitoring the operator panel in the controller. (Function similar to coordination area in Siemens S7.)
Numeric variables can be displayed as predefined text for example alarms, sequence steps etc.
Detailed diagnostics of connection and communication.
Variable areas for system variables, local variables and constants.
Possibility of automatic return to the start page after some time of inactivity.
Selectable order for high and low words of 32-bit variables in the Modbus protocol.
Poll interval can be set do save data traffic or battery.
Support for Greek, Turkish, Baltic, Central European, Eastern European, Cyrillic, Japanese (Shift JIS) and Chinese (GB2312, BIG5) character sets.
Ability to test run (pages in the development tool.
LED-objects can be displayed as rectangles and in any size e.g. for Andon-systems.
Background color for pages can be selected.
Modbus Slave Id can be changed with GUI objects during operation.
Image buttons.
Password fields.
Floating point and hexadecimal number formatting.
Timestamp for page files.
Hyperlinks.
Document information in page files.

Implemented protocols in the current version:

Modbus/TCP: Class 0, Function 3 and 16. Reads and writes 64,512 holding registers.

Modbus/TCP: Class 1, Function 1, 2, 4 and 5. Reads 65,535 discrete inputs, 65,535 input registers and reads and writes 65,535 outputs (coils).

Modbus RTU: Class 0 and 1.

Siemens S7 Communication: Reads and writes 8192 bytes in datablock 1 to 4095 and in the Input, Memory and Output areas.

(Default value for highest Siemens S7 databock is 255.)

Free-of-charge development tool for creating the pages to be run by Odrid HMI:
https://www.idea-teknik.com/odrid_hmi_download.html

Manual:
https://www.idea-teknik.com/odrid_hmi_manual.html

Version history:
https://www.idea-teknik.com/odrid_hmi_version_history.html

Modbus and Modbus/TCP are registered trademarks of Schneider Automation Inc.

Neuheiten

Version 1.7.9

1.7.9:

Bug fixes/improvements in the protocol drivers for Modbus and Siemens S7 Communication (ISO-on-TCP).

1.7.8:

Error messages for different Siemens S7 String issues.
Bug fix for system register 65452 (last Siemens S7 polled DBNO).
Bug fix for lighted push button with a non zero register offset.
The term 'Panel' is changed to 'Page'.

Bewertungen und Rezensionen

1,0 von 5
1 Bewertung

1 Bewertung

derRobert85 ,

Einfach Klasse

Endlich habe ich diese Software entdeckt.
Somit Ist die Logo! von Siemens endlich zur Haussteuerung geeignet und das ohne einen aufgeblasenen Heimautomatisierungsserver.

Das Erstellen der HMI Oberfläche in der Kostenfrei zur Verfügung gestellten Studiosoftware ist gewöhnungsbedürftig aber nach etwas Einarbeitung und dank der Super Hilfe der Entwickler klappt das dann ganz gut.

Ich bin begeistert. Mit dieser Software konnte ich innerhalb weniger Tage ein lang erträumtes Projekt umsetzen und bin voll zufrieden.

Der Support vom Entwickler ist erstklassig und super schnell.

Eigentlich zu gut und zu schnell für den niedrigen Preis.
Ich glaube man verkauft sich hier unter wert.

Mgg12345778 ,

easyE4

Wir nutzen die App zur Visualisierung einer Eaton easy E4 SPS. Die Kommunikation läuft über TCP/Modbus Class 1.

Das System läuft sehr stabil.

Kleinere Probleme werden durch den Entwickler im direkten Kontakt extrem schnell beantwortet.

Für die App und den Support vergebe ich gern 5 Sterne!

Sindbad-de ,

Perfekt

Ich habe meine Siemens Logo damit verbunden, läuft super.

App-Datenschutz

Der Entwickler, Jan Almqvist, hat darauf hingewiesen, dass die Datenschutzrichtlinien der App den unten stehenden Umgang mit Daten einschließen können. Weitere Informationen findest du in den Datenschutzrichtlinien des Entwicklers.

Keine Daten erfasst

Der Entwickler erfasst keine Daten von dieser App.

Die Datenschutzpraktiken können zum Beispiel je nach den von dir verwendeten Funktionen oder deinem Alter variieren. Weitere Infos

Support

  • Familienfreigabe

    Bis zu sechs Familienmitglieder können diese App bei aktivierter Familienfreigabe nutzen.

Das gefällt dir vielleicht auch

ModTest Pro
Produktivität
irBoard Lite
Produktivität
SIMATIC Notifier
Produktivität
Sm@rtClient
Produktivität
Arduino Manager
Produktivität
TCP UDP Ping工具 Socket网络调试工具
Produktivität