REALITi is a new simulation ecosystem incorporating a realistic patient condition simulator and video review in a single system.

Starting with 2 iPads, REALITi is a highly advanced patient monitor simulator which mimics proprietary monitors and defibrillators.

By expanding the system with more iPads, a complete in-situ simulator can be created.

Add REALITi Chart to use a simulated patient electronic medical record.

Add REALITi Camera to incorporate live audio video streaming with vital sign display. Optionally stream via AirPlay to Apple TV. Instant video review once the simulation has ended is built into the system.

Add REALITi Engage to allow observers to comment, vote and view media.

Features:

• Easy to use Dial and Button interface.
• Over 75 ECG waveforms
• Dynamic 12 lead ECG library.
• Comprehensive Radiology image library with over 250 images.
• Extensive and configurable laboratory results library.
• Simulate ectopics, sinus arrhythmia, artefacts and interference on the ECG with ease.
• Easy to use Checklist interface for simple student assessment.
• Easy scenario creation with single screen scenario running and editing.
• Many defibrillator and monitor screens included.
• CPR Feedback
• QCPR Screen

ATLAS ALS Manikin compatible

Τι νέο υπάρχει

Έκδοση 11.6.0

Multiple Screens
- Improved logs window performance when lots of logs.
- Enabled unit measurements' conversion in IBP and NIBP of the following monitors: Zoll R, Philips MRx, Schiller Defigard Touch7, Generic Monitor, Generic Defib, Generic Wave, Generic Numerics, GE Carescape B850, Philips IntelliVue MX800 and WelchAllyn Connex.
- Monitors that do not support the conversion to unit cmH2O will remain as mmHG.
- Resolved issue in Schiller Defigard Touch7 where NIBP value gets changed by the conversion toggle button in CO2 in Unit Measurements
- Enabled Pacer Settings' Default Output and Rate for Zoll Propaq MD, Zoll X, Schiller Defigard Touch 7 and Tempus LS.
- Enabled Pacer Settings' Remember Last Output and Rate for Zoll Propaq MD, Zoll R, Zoll X, Schiller Defigard Touch 7 and Tempus LS.
- Fixed ECG waveform not being changed if the new waveform was the same as the previously loaded scenario.
Capnostream 35
- Resolved crash issue on starting Capnostream 35.
Corpuls 3/3T
- Fixed issue with metronome count not reverting to original configured ratio.
- Fixed issue with Start Analysis being played just after powering on, no delay.
- Fixed issue with metronome not resetting to Adult 30:2 when C3/C3T is powered off.
Hamilton T1
- Changed F Total b/min from decimal to integer in Alarms.
- Changed F Total b/min from decimal to integer in the Monitoring section.
Lifepak 15
- Resolved issues on NIBP countdown timer and MAP display overlap.
- Enabled reset on contrast when the monitor is turned off.
- Resolved issues with the Home and high-contrast Sunvue buttons, where the lower portion was unresponsive to clicks.
- Resolved crash issue when changing back from high contrast Sunvue display to color display.
- Resolved issue on metronome.
- Enabled correct state for CPR button when switching from AED to manual defibrillator.
Revel Vent
- Resolved issue on audible tone looping after swiping from left to exit the ventilator.
Schiller Defigard Touch 7
- Enabled flashing alarm light and parameter field flashes in the secondary Pulse field when limits are - exceeded.
- Enabled alarm light flash for HR.
- Added heart icon in the second Pulse parameter field
- Fixed primary Pulse background to blue when changing from HR to Pulse.
- Resolved issue on secondary Pulse not changing to dashes when Control’s finger probe is off.
- Resolved issue on HR, SpO2 and Pulse not flashing in both alarm light and parameter fields when limits are - exceeded.
- Fixed issue on primary Pulse not changing back to HR field when the source is AUTO and becomes unhidden.
Zoll R
- Resolved issue on “NIBP MEAS ABORTED” message appearing when NIBP value in Control Parameter Settings is changed.

Απόρρητο εφαρμογής

Ο δημιουργός «iSimulate Pty Ltd» υπέδειξε ότι οι πρακτικές απορρήτου της εφαρμογής ενδέχεται να περιλαμβάνουν τον χειρισμό δεδομένων όπως περιγράφεται παρακάτω.Για περισσότερες πληροφορίες, δείτε την πολιτική απορρήτου δημιουργού.

Δεδομένα που συνδέονται με εσάς

Τα ακόλουθα δεδομένα μπορεί να συλλεχθούν και να συνδεθούν με την ταυτότητά σας:

  • Διαγνωστικά

Οι πρακτικές απορρήτου μπορεί να διαφέρουν, για παράδειγμα, βάσει των δυνατοτήτων που χρησιμοποιείτε ή της ηλικίας σας. Μάθετε περισσότερα

Περισσότερα από αυτόν τον δημιουργό

AURiS
Εκπαίδευση
iSimulate Community
Βοηθήματα
POC-kit
Εκπαίδευση
REALITi Engage
Εκπαίδευση

Ίσως σας αρέσει επίσης

qube15 by SKILLQUBE
Εκπαίδευση
qube20e by SKILLQUBE
Εκπαίδευση
corpuls simulation
Εκπαίδευση
TabletAED trainer
Εκπαίδευση
SAM4 Online
Εκπαίδευση
FOAMfrat Studio
Εκπαίδευση