REALITi 17+

iSimulate Pty Ltd

iPad용으로 디자인됨

    • 무료

iPad 스크린샷

설명

REALITi is a new simulation ecosystem incorporating a realistic patient condition simulator and video review in a single system.

Starting with 2 iPads, REALITi is a highly advanced patient monitor simulator which mimics proprietary monitors and defibrillators.

By expanding the system with more iPads, a complete in-situ simulator can be created.

Add REALITi Chart to use a simulated patient electronic medical record.

Add REALITi Camera to incorporate live audio video streaming with vital sign display. Optionally stream via AirPlay to Apple TV. Instant video review once the simulation has ended is built into the system.

Add REALITi Engage to allow observers to comment, vote and view media.

Features:

• Easy to use Dial and Button interface.
• Over 75 ECG waveforms
• Dynamic 12 lead ECG library.
• Comprehensive Radiology image library with over 250 images.
• Extensive and configurable laboratory results library.
• Simulate ectopics, sinus arrhythmia, artefacts and interference on the ECG with ease.
• Easy to use Checklist interface for simple student assessment.
• Easy scenario creation with single screen scenario running and editing.
• Many defibrillator and monitor screens included.
• CPR Feedback
• QCPR Screen

ATLAS ALS Manikin compatible

새로운 기능

버전 11.4.0

Zoll R
- Added settings to support 3 leads, filtered ECG, SpO2 and EtCO2 based on settings
- Updated labels and layout to support 3 leads
- Corrected pacing to single trace
- Renamed Leads to ECG
- Renamed Filt ECG to FIL
- Improvements to display when using Trace 3 with CPR
- Modified prompts that were obstructing waveforms
- Adjusted pacing output to increments of 2 instead of 5
- Fixed overlap on Trace 3 with Sync on
- Corrected sync background colors when defib is on
- Improvements to EtCO2:
- Added zeroing
- Adjusted timers
- Added CO2 warm up
- Corrected EtCO2 button behaviour
- Changed ECG sync symbol from S to triangle
-
Settings
- Added settings for Trace 2 and 3

Zoll X
- Correct missing display elements when in high contrast mode

Zoll EMV
- Enabled two-way control
- Tidal volume, Fi02, BPM, and mode changes on the device can now adjust the facilitator

Schiller Defigard Touch 7, Schiller Physiogard Touch 7 & Zoll X
- Improvements to IBP alarms and timers
- Added ability to zero art. line

LIFEPAK 15
- Fixed UI glitch that caused a thin line on CO2 tracing

Corpuls 3
- Disabled jog dial flash when device is turned off
- Improved pie chart on manual defib and AED
- Enabled Cancel button after Analyse button is pressed
- Improvements to manual defib timer and pie chart
- Resolved an issue with waveforms not editable after switching to manual mode

Corpuls AED
- Fixed an issue with analysis running when not expected.
- Updated analysis button LED states to better replicate the device

Corpuls 1, Corpuls 3, Corpuls 3T & Corpuls AED
- Handled Empty fields in manual mode

Facilitator
- Fixed missing positions for manual electrode placement on iPad Mini
- Resolved an issue with patient weight and temperature not displaying correctly when activating scenarios
- Improved Chinese translations

SimConnect
- Improvements to connection, finger detection and stacked breaths
- SimConnect is no longer displayed as a CPR band
- Fixed bug that caused ETCO2 to trend to 0 after ventilation
- Added ability to change name of SimConnect
- Added interface for selecting adult or neonatal flow probe

SimConnect & Zoll X
- Corrected handling for trace of SpO2 after probe disconnected
- Added labels to Zoll X to support SimConnect:
- Check sensor
- Initializing
- Calibrating
- Searching
- Corrected SpO2 start up behaviour to support integration of SimConnect

Settings
- Fixed overlapping text in settings drop downs
- Resolved an issue where settings were not saved correctly

Atlas Junior
- Enabled pulse during compressions
- Removed unnecessary quotation marks from WiFi config

Atlas facilitator
- Connections panel:
- Updated name to “ATLAS”, previously “ATLAS Senior”
- Added ability to see WiFi SSID in connection settings

앱이 수집하는 개인정보

iSimulate Pty Ltd 개발자가 아래 설명된 데이터 처리 방식이 앱의 개인정보 처리방침에 포함되어 있을 수 있다고 표시했습니다. 자세한 내용은 개발자의 개인정보 처리방침을 참조하십시오.

사용자에게 연결된 데이터

다음 데이터가 수집되어 신원에 연결될 수 있습니다.

  • 진단

개인정보 처리방침은 사용하는 기능이나 사용자의 나이 등에 따라 달라질 수 있습니다. 더 알아보기

이 개발자의 앱 더 보기

AURiS
교육
REALITi Engage
교육
iSimulate Community
유틸리티
POC-kit
교육

좋아할 만한 다른 항목

qube15 by SKILLQUBE
교육
qube20e by SKILLQUBE
교육
corpuls simulation
교육
qubeZERO by SKILLQUBE
교육
FOAMfrat Studio
교육
quberMS2 by SKILLQUBE
교육