![](/assets/artwork/1x1-42817eea7ade52607a760cbee00d1495.gif)
Oxyg'App 4+
L'Institut universitaire de cardiologie et de pneumologie de Québec (IUCPQ)
專為 iPhone 設計
-
- 免費
iPhone 螢幕截圖
描述
Oxygen management should rely on oxygenation targets, with minimal and maximal boundaries to avoid both hypoxemia and hyperoxemia. Oxygen titration using targets based on arterial saturation (SaO2) are not feasible due to discontinuous measurements of this parameter that requires an arterial blood gas analysis. The oxygen support must be titrated based on SpO2 that allows continuous measurements of patient oxygenation, even though this technology has limitations and needs improvement. We may hope for a major technological evolution as the main working principles of this technology, which are more than 50 years old, have not changed appreciably. Waiting for this improvement in pulse oximetry technology, clinicians should tread carefully and apply algorithms to correct for these deficiencies. Whatever the clinician thinks is the appropriate oxygenation target, this "optimal SaO2" target needs to be corrected when utilizing the SpO2 for the titration based on skin pigmentation and oximeter brand. It has become increasingly apparent that the SpO2 target cannot simply be the SaO2 target!
To facilitate the quest of the optimal SpO2 targets and to promote a more homogeneous management of patients’ oxygenation regardless of skin pigmentation or monitoring device of oxygenation there are several potential solutions. We believe that one SpO2 target does not fit all patients and that further clinical trials and clinical guidelines should use corrected SpO2 targets rather than universal targets for all patients. Consequently, clinicians should first define a SaO2 target relative to the patient under respiratory support and then apply corrections for the mean bias related to the skin pigmentation and to the oximeter used to get the corrected SpO2.
最新功能
版本 1.0.2
Adding a warning to emphasize educational intent.
App 私隱
開發者表明L'Institut universitaire de cardiologie et de pneumologie de Québec (IUCPQ)的私隱慣例或包括下列資料的處理。詳情請參閱開發者的私隱政策。
與你連結的資料
開發者可能會收集以下資料並連結你的個人身份:
- 聯絡資料
不會與你連結的資料
開發者可能會收集以下資料,但不會連結你的個人身份:
- 診斷
私隱慣例或因使用的功能或年齡等因素而異。進一步了解
資料
- 供應商
- Institut universitaire de cardiologie et de pneumologie de Quebec
- 大小
- 33.8 MB
- 類別
- 教育
- 兼容性
-
- iPhone
- 須使用 iOS 13.0 或以上版本。
- iPod touch
- 須使用 iOS 13.0 或以上版本。
- Mac
- 須使用 macOS 11.0 或以上版本及配備 Apple M1 或以上版本晶片的 Mac。
- Apple Vision
- 須使用 visionOS 1.0 或以上版本。
- 語言
-
英文
- 年齡
- 4+
- Copyright
- © 2023 Institut universitaire de cardiologie et de pneumologie de Québec - Université Laval
- 價格
- 免費