quberMS2 by SKILLQUBE 4+

SKILLQUBE GmbH

專為 iPad 設計

    • 免費

螢幕截圖

描述

In cooperation with WEINMANN Emergency Medical Technology, a ventilation simulator based on MEDUMAT Standard2 has been developed. MEDUMAT Standard2 is used in the rescue service, air rescue or in the military medical service.

Skillqube has many years of experience in the development of holistic simulation solutions as well as in the training and continuing education of emergency services personnel. Both companies would like to contribute significantly to the increase of patient safety and the saving of human lives through the development of simulation systems.

The ventilation simulator qubeMS2 complements the current simulation products of the qubeSERIE, which includes ECG simulators based on the Corpuls3, LIFEPAK15 and DEFIGARD Touch7.

最新功能

版本 5.0.0

Controller
* New ECG WPW 3
* Device activation revised (larger field / more fluid / search option / confirmation prompt)
* Scenarios can now be searched for (text input)
* SpO2 amplitude can be set in % (100% full deflection / 0% no deflection)
* Revision of the folder structure for a better overview & easier navigation
* Optimization of the slider movement (smoother)
* Folder of the ECG database visible again despite double connection
* Additional media such as MP4 etc. are now allowed

Performance improvements
* Switch on MS2 via CPR button
* Display optimization qubeMS2 I:E
* Challenges with the stage manager and swipe gestures improved
* Battery Low Alert revised with more information

General improvements
* Implementation of new CI
* Pulse perfusion is stabilized when setting trend vital signs
* Translations optimized
* Adjustments to the Bluetooth connection to the qubeAirflow / visibility
* Adjustments to the CPR dashboard (group selected directly)
* Autoscaling of waveforms adjusted to avoid disappearance
* Optimization of the keyboard overlay
* UX/UI optimization when leaving the CPR screen without a connected monitor
* Optimization PDF export logbookIn the connection center, the names of the devices are displayed better visually
* Already connected monitors are removed from the Connection Center (or packed into another list "Systems already connected to other controllers")
* FURTHER IMPROVEMENTS
* Stability and display of connected sensors
* Display of blood pressure values from the previous scenario


qubeSerie Monitor general
* Adjustment of the standard J number for defibrillation that can be set in the cloud (qubeC3/C3T, qube7 limited to 200J)
* Optimized display of the J number

qube15
* Amplitude setting qube15 (larger smaller)
* Shock LED is displayed again
* ECG lines now stand still when no ECG is connected

qubeR
* Loading of the Joule number adapted to the set energy
* Display of alarm limits optimized

qube20e
* Start mode of the qube20e adjusted (open/closed valve)
* Automatic triggering of cardioversion after switching to AED has been fixed


qubeC1/C3
* Revision of the defibrillator unit
* Jugdial in manual/AED mode has been revised

qubeAssessment
* Connecting the assessment no longer triggers an analysis in the AED

qubeCTG
* Optimization of the display when opening the CTG as a monitor
* Fetal heart rate and temperature are now displayed correctly on the 10.2" iPad

qubeZero
* Pacer optimized (FIX/Demand)

MRx
* New monitor

App 私隱

開發者表明SKILLQUBE GmbH的私隱慣例或包括下列資料的處理。詳情請參閱開發者的私隱政策

不收集資料

開發者不會從此 App 收集任何資料。

私隱慣例或因使用的功能或年齡等因素而異。進一步了解

更多此開發者的出品

qubeT1 by SKILLQUBE
教育
qubeAED by SKILLQUBE
教育
qube20e by SKILLQUBE
教育
qubeVENT by SKILLQUBE
教育
qubeASSESS by SKILLQUBE
教育

你可能也喜歡

corpuls simulation
教育
Prüfungshilfe Notfallsanitäter
教育
RetSan Lernen
教育
SAA & BPR 2023
參考
Rettungsdienst Guide
參考
REALITi
教育