EuroSoft live from SYSTRONIK GmbH (member of the AFRISO-EURO-INDEX group) allows for easy and convenient visualisation of the live measured values of your CAPBs measuring instrument. The measured data is transmitted to your mobile device via Bluetooth® Smart. The measured values are displayed in application programs and can be shared in reports. This app can read the live measured data of the following devices:
- CAPBs AQ20, AQ35, AQ36
- CAPBs CO30
- CAPBs FP10
- CAPBs GS10, GS11 GS15, GS40
- CAPBs PS10, PS20, PS22, PS33, PS35, PS40, PS41, PS42, PS60, PS61, PS62
- CAPBs PT70, PT85, PT86
- CAPBs RH80
- CAPBs TK10, TK11, TK20, TK30, TK35, TK40, TK50
- CAPBs WQ10, WQ11
- FlowTemp ST, FlowTemp STx
- VA100
more Bugfix:
- Barometric pressure for PS33 is displayed again (leakage rate applet)
- Device calibration values for WQ10 / WQ11 are displayed again
- The values above were not displayed in the corresponding dataview
- Fix displaying max concentration value for selectable refrigerants in gas leakage measurement applet
3.5.1 Jul 23
New features:
- New CAPBs GS11 for gas leakage detection
- New CAPBs GS15 and GS40 for refrigerant leakage detection
Improvements:
- Major Update of Qt library
- Improved permission handling
- Small performance improvements for applet loading
- Added support for high resolution tablets
- Improved CAPBs autoconnect feature
3.5.0 Jul 14
Bugfixes:
- Fixed coverage of app components by the native navigation/status bar
- Fixed issues with the FlowTemp applets
- Waterquality applet fixed pH4/10 calibration
- Prevent start a measurement before chart config is loaded
- Improved workflow and visual appearance of DIN EN 12599 Applet
- The checkbox for selecting a connection is set correctly when the application starts
3.4.2 Apr 13
New features:
- Added new BLE anemometer VA100
- Added new applet for airflow measurement after DIN EN 12599
- Added new valves for hydraulic balancing (Hertz, Caleffi, GENEBRE, Gampper)
- New unit "inch W.C." for pressure applets
Bugfixes:
- Fixed measurement report issues including report titles
- Waterquality applet fixed pH4/10 calibration
Improvements:
- Waterquality calibration command delayed
3.4.1 Mar 19
New features:
- Added new BLE anemometer VA100
- Added new applet for airflow measurement after DIN EN 12599
- Added new valves for hydraulic balancing (Hertz, Caleffi, GENEBRE, Gampper)
- New unit "inch W.C." for pressure applets
Bugfixes:
- Connection panel on widescreens fixed
- Fixed measurement report issues
- Fixed reading service QR-Code for CAPBs device
Improvements:
- Waterquality calibration command delayed
3.4.0 Mar 16
Improvements:
- WQ10: pH calibration with error message when exceeding range
- Hydraulic balancing: Valve selection is editable again
- VDI2035: Adjusted limit values for aluminum components
Bugfixes:
- Project management: Stored orders export possible again
- Service company logo is saved correctly
- PDF generation: Improved error handling
- Multi-measurement: Export and storage corrected
- More stable share function
3.3.1 11/07/2025
Features & improvements:
- Valve balancing applet: Support for additional valve types (Resideo, FlowCon)
- Water quality applet: VDI2035 standard extension
- Leakage rate applet: Correct result on sharepage
- Project management: Improved database functions (deletion)
- Design update of measurement data field
Bug fixes:
- Possible application crashes fixed
- BLE more stable connection establishment
3.3.0 10/15/2025
Improvements:
- Fix issue with XL tablet displays not showing connection menu button
- Add new FlowCon valves to hydraulic balancing applet
- Waterquality: Added better description to set manual total hardness
- Added description to project management applet (help button)
- Fix calcualtion of Q-Flow in FlowTemp applets
- Fix possible crash in normative pressure applet
- further internal fixes
3.2.3 06/02/2025
Bugfixes:
- Fixed not translating measurement result
- Fixed problems displaying umlauts in normative pressure applet
- Fixed not working numeric text inputs (hygiene flushing)
- Fixed not updating settings values in water quality applets
- Fixed result in normative pressure applet
Improvements:
- Double the time to temperature consistency (hygiene flushing)
- show result combobox on sharepage
3.2.2 10/25/2024
Bugfix:
- Multi measurement list visiblity, location information in report
- Camera on share page
- Connection problems with CAPBs
New functions:
- Project management feature available for all FlowTemp applets
Improvements:
- internal library updates
- QR Code applet improvements
- Sharepage improvements
3.2.1 09/04/2024
New functions:
- Project management feature available for all FlowTemp applets
- Added FlowTemp STx demo device for testing
- Project management is currently free of charge
- Multi measurement better workflow
- Water quality added timer for pre conditioning
Improvements:
- internal library updates
- Improvements in the selection of locations, rooms and measuring points
- QR Code applet improvements
- Sharepage improvements
3.2.0 08/19/2024
Bugfix:
- Diagrams in multi measurement report exports are now the correct diagrams to the measurement
3.1.3 11/13/2023
Fixes:
- Pressure tests applet fixed "new measurement" function
Improvements:
- Water quality applet reset pH validation values on device when values are completely out of bounds
3.1.2 11/07/2023
Fixes and improvements:
- CAPBs FP10 added as compatible device to Temperature applet
- Do not show location contact information in multi measurement
- More space for result title in pdf
- Resetting of result and photos on share page fixed
- Location undo function restored
- Selecting photos from gallery fixed
- fix potential crash on changing device orientation during share procedure
- improve pH validation WQ10
3.1.1 10/27/2023
New features:
- Multi-measurements are now available:
- Perform new measurement
- A "Save" button is displayed
- Location information can be entered when saving
- List and detail view of measurements are available
- Multi Share is also available
- Now 2 photos are possible as attachments
- Water quality demineralized water no hardness calculation
Improvements:
- QR code recognition improved
- Improved workflow in normative pressure testing applet
- Important library upgrades
3.1.0 09/28/2023
News:
- New major version 3.0.0
- major UI / UX update in Material style
- input elements reworked for better usability / appearance
- Navigation in applets reworked
- assistant in measurement applications reworked, advancing now from left to right
- more discrete color theme
Improvements:
- Leakage rate test optimized and enabled for NL
- FlowTemp diagram configuration optimized
- New translations added
- Stocker and FlowCon IVC valves added to Hydraulic balancing
- other small improvements
3.0.0 04/04/2023
2.11.2 Hotfix:
- Fix for measurement data view in pressure test applets
2.11.1 Hotfix:
- Prevent app from possible crash on applet change
- Improve measurement display thermal disinfection
2.11.0 Highlights:
- New applet thermal disinfection
- Water quality applet add new CAPB WQ11
2.11.0 Improvements:
- Gas leakage applet improved detection fresh air
2.11.2 12/13/2022
2.11.1 Hotfix:
- Prevent app from possible crash on applet change
- Improve measurement display thermal disinfection
2.11.0 Highlights:
- New applet thermal disinfection
- Water quality applet add new CAPB WQ11
2.11.0 Improvements:
- Gas leakage applet improved detection fresh air
2.11.1 12/01/2022
Highlights:
- New applet thermal disinfection
- Water quality applet add new CAPB WQ11
- Water quality applet add pH 7 / pH 10 calibration
- Auto connection to nearest CAPBs after search
- Take images from in app camera for report
Improvements:
- Gas leakage applet improved detection fresh air
- Hydraulic balancing new valves (VIR)
2.11.0 11/26/2022
Highlights:
- New applet temperature profile for FlowTemp ST/STx
- New applet contact data (service company and customer data)
Improvements:
- PDF report file name adjusted: e.g. 20220601_120000_Report.pdf
- PDF report contains filename in document footer
- Improved behavior if FlowTemp ST/STx tilt angle sensor hits
- Internal library update and improvements
2.10.0 07/08/2022
Improvements:
- Gas leakage measurement improved fresh air behavior
2.9.3 04/11/2022
Highlights:
- CAPBs device Bluetooth compatibility added (after firmware update)
- New applet anode tester
- Hydraulic balancing Introduction of dynamic valve settings
- Bluetooth connection significantly improved
Improvements:
- Gas leak measurement, automatic baseline correction
- Improvements in the FlowTemp applet
- 4 Pa test no longer shows a temperature value (FP10)
Bugfixes:
- FT21 Endianess
- QRCode applet visibility
- Fixed possible crash on unit change
2.9.2 02/04/2022
Highlights:
- CAPBs device Bluetooth compatibility added (after firmware update)
- New applet anode tester
- Hydraulic balancing Introduction of dynamic valve settings
- Bluetooth connection significantly improved
Improvements:
- Gas leak measurement, automatic baseline correction
- Valve adjustment preparation for measurement explained
- Improvements in the FlowTemp applet
- 4 Pa test no longer shows a temperature value (FP10)
Bugfixes:
- FT21 Endianess
- QRCode applet visibility
2.9.1 01/26/2022
Highlights:
- CAPBs device Bluetooth compatibility added (after firmware update)
- New applet anode tester
- Hydraulic balancing Introduction of dynamic valve settings
- Bluetooth connection significantly improved
Improvements:
- Gas leak measurement, automatic baseline correction
- Valve adjustment preparation for measurement explained
- Improvements in the FlowTemp applet
- 4 Pa test no longer shows a temperature value (FP10)
- Internal library update and improvements
2.9.0 01/21/2022
Highlights:
- CAPBs module button press steps through applet steps
Improvements:
- Internal library update and improvements
Bugfixes 2.8.1:
- Zeroing of pressure CAPBs improved
- Deactivating single graphs in diagram of FlowTemp applet
Bugfix 2.8.2:
- FlowTemp STx (FT21) measurement data are interpreted correctly again
2.8.2 10/27/2021
Bugfix:
- Barometric pressure for PS33 is displayed again (leakage rate applet)
- Device calibration values for WQ10 / WQ11 are displayed again
- The values above were not displayed in the corresponding dataview
- Fix displaying max concentration value for selectable refrigerants in gas leakage measurement applet
more Version 3.5.1 Jul 23