ANSWatch Mini

ANSWatch Mini

Free · Designed for iPad. Not verified for macOS.

This app is available for EU and Taiwan only at this time. The medical device ANSWatch Mini is approved by Taiwan FDA and CE Mark for hardware and software. More countries and regions will be added as the regulatory approvals are granted. The ANSWatch Mini app communicates and controls ANSWatch-Mini wrist monitor via Blue-tooth wireless. In about 6 minutes, the setup obtains the vital physiological parameters of human body, including Systolic pressure, Diastolic pressure, Heat rate, Irregular heartbeat (which could contain cardiac arrhythmias), and Heart rate variability HRV. HRV parameters are highly related to the activities of the autonomic nervous system ANS. The app will record 5-minute complete pulse waves with irregular heartbeats automatically marked. All measured physiological parameters are also automatically ranked based upon our proprietary clinical database and AI.

  • This app hasn’t received enough ratings or reviews to display an overview.

1. You can now back up and restore your data through the Files app. 2. Fully compatible with iOS 18. 3. Performance and stability improvements for a smoother experience.

The developer, Taiwanscientific, indicated that the app’s privacy practices may include handling of data as described below. For more information, see the developer’s privacy policy .

  • Data Not Collected

    The developer does not collect any data from this app.

    Privacy practices may vary, for example, based on the features you use or your age. Learn More

    The developer has not yet indicated which accessibility features this app supports. Learn More

    Seller
    • Taiwan Scientific Corporation
    Size
    • 35.9 MB
    Category
    • Health & Fitness
    Compatibility
    Requires iOS 11.0 or later.
    • iPhone
      Requires iOS 11.0 or later.
    • iPad
      Requires iPadOS 11.0 or later.
    • iPod touch
      Requires iOS 11.0 or later.
    • Mac
      Requires macOS 11.0 or later and a Mac with Apple M1 chip or later.
    Languages
    • English
    Age Rating
    4+
    Medical Device
    Yes
    • Taiwanscientific indicated this app is a regulated medical device and complies with United States law.
    • The information below has not been verified by Apple.
    • FDA Owner/Operator Number
    • 10094834
    • Address
    • Taiwan
      23141 New Taipei City 10f, 88-4, Ming-Chiuan Rd.,
    • Phone Number
    • +886 953 933 962
    • Email
    • sundc@hotmail.com
    • Use Statement
    • ANSWatch-Mini Wrist Monitor
      ModelTS-0411; Size: Mini
      - Product Specification –
      Date: 2017-12; Version: 01

      Specifications of ANSWatch -Mini Wrist Monitor
      Manufacturer: Taiwan Scientific Corp.
      Sales Agent: Taiwan Scientific Corp.
      Product Model: TS-0411Mini-size
      Product Name: ANSWatch -Mini Wrist Monitor
      Registered Trade Name in Taiwan: Taiwan Scientific Non-invasive blood pressure meter (ANSWatch) /台灣科學地-非侵入式非侵入血壓測量儀 (心律大師)
      Registered Trade Name in USA: Taiwan Scientific Non-invasive blood pressure meter (HRVWatch)
      Registered Trade Name in EU: Taiwan Scientific Non-invasive blood pressure meter (ANSWatch)
      Warranty: 1-year (or per contract); Wrist cuff, bio-sensor module, and battery pack are disposable parts and not covered in warranty).
      Product photos:


      Product specification
      Model: TS-0411; Size: Mini
      Physical dimension: Length 7 cm x width 5 cm x thickness 2 cm (cuff not included)
      Weight: 75 g
      Power: rechargeable lithium battery; Battery pack rating 3.7V, 500mA max. current)
      Battery capacity: 250 mA*Hr (more than 15 tests per full charge; power-off stand-by 30 days or longer)
      Charge cable: USB 2.0 charge cable (USB to Micro USB)
      Charge time: 4 hours
      Charge port: Micro-USB (Virtual COM Port 及 USB)
      Blue-tooth wireless: support Blue-tooth 4.0 and above for BLE-type connection
      Android OP: support Android 4.2 (Ice Cream Sandwich) and newer versions
      iOS OP: support 9.0 or newer versions
      Windows: support XP, Vista, 7, 8, and 10
      Database: patient data automatically saved in the database established in a smart phone or tablet (accessible to third-party programs)
      Data upload/cloud: patient data uploading to server/cloud manually controlled by user
      Patient parameters measured: Systolic Pressure, Diastolic Pressure, Heart Rate, Irregular Heartbeats, Heart Rate Variability (HRV) (including ANS total activity index HRV, para-sympathetic nerve activity index High Frequency Component (HF), sympathetic nerve activity index Low Frequency Component (LF), and sympathetic-parasympathetic balance index LF/HF).
      Physiological parameters Accuracy:
      Blood pressure range and accuracy: 50-180 mmHg (+ 8 mmHg)
      Heart rate range and accuracy: 40-250 beat/min (+ 1 beat/min)
      HRV range and accuracy: 0-999 ms (+ 5%)
      HF% range and accuracy: 0-100% (+ 5%)
      LF% range and accuracy: 0-100% (+ 5%)
      LF/HF range and accuracy: 0-999 ((+ 5%)
      Number of irregular heartbeats: 0-999 (+ 1)

      Operating environment: max. temperature 40C
      Transport/storage conditions: temperature 5-40 oC ; humidity 0-100%
      Maximum altitude above sea level 3000 M; Atmospheric pressure 700hPa-1060hPa
      For indoor use only


      Refer Manual Consult instructions for use Type BF Applied part (cuff)


      Product certification
      Taiwan FDA; US FDA; ISO 13485; CE Mark; IEC EN60601-1; IEC EN60601-1-2

      Warranty
      ANSWatch products are sold with a one-year (12-month) limited warranty. Within the warranty period, if your product does not work properly because of a defect in materials or workmanship, we will repair your product with new or refurbished parts or replace it with a new or a refurbished product. Customers should contact their sales representative first to arrange for carry-in or mail-in service. There will be no charge for labor, parts, or 2-way return shipping. The limited warranty does not cover normal wear, mechanical damage, or water damage. Warranty is invalidated if the product cover fixed by screws has been opened. Product repair with a charge is available for work not covered in the warranty. Contact your sales representative for details.
      --------------------------------------------------------------------------------------
      Product Warranty
      (一) This product carries one-year limited warranty (parts, labor, and return two-way shipping)
      (二) Water, fire, and mechanical damages are excluded from coverage. Repairs with a charge are available
      (三) Contact your sales representative for carry-in or mail-in instructions

      Product model: __________________________________________
      Device ID: ______________________________________________
      Sales representative: ______________________________________
      Date of purchase: __________________________________________


      Manufacturer: Taiwan Scientific Corporation, 10F, 88-4, Ming-Chiuan Road, Shin-Dian District, New Taipei, Taiwan 231

      Authorized EU Representative (EUR): Orthoplastics Ltd, Grove Mill, Todmorden Road, Lancashire, OL13 9EF, UK


      All rights reserved, Taiwan Scientific Corp., 2017-12.
      (For EU countries requiring a regional or local language other than used in this document, please contact our local representative for availability of IFU in your language; Free auto translation service from our e-User’s Manual is in general provided by Google Translate at https://translate.google.com/)

    • Safety Information
    • Precaution before use
       The device is to be used by customers under the supervision of a professional
       ANSWatch battery must be charged before use (Use a qualified charging cable and adaptor only).
       Do not substitute professional instructions with self-interpretation. Test results of blood pressures, heart rate variability (autonomic nervous system functions), and irregular heartbeats should be analyzed by physicians or health professionals who understand your health condition.
       If you are currently taking medicine, consult with your doctor to determine the best times for conducting blood pressure and heart rate variability tests. *Do not stop taking or switch medicine without your doctor’s permission.
       ANSWatch is designed for use by adults. Tests for children must be conducted under a health professional’s supervision. *ANSWatch should never be used on babies.
       To improve data consistency, efforts should be made to conduct tests under similar conditions at same time zones of the day. Avoid time periods of before meal, after meal, or after heavy exercise. Suggested time periods for testing are: 9 ~ 11:30 AM, 2 ~ 6 PM, and 8 ~ 10 PM. Rest for at least 15 minutes between two consecutive tests.
       To prepare for a test, remove any wearing (watch, jewelry, etc.) on the left wrist. Lie down or sit comfortably for 10 minutes. When ready, wear ANSWatch-Mini on your left wrist according to instructions in this User’s manual.
       During the test, keep quiet and maintain stable. *No talking or body movement is allowed. Close your eyes for better results. It has been noted that blood pressures could be affected by muscle tightness or postural change. Autonomic nervous system could also respond to environmental, physical, or mental disturbances.
       Keep the product and package in its “original” condition in case of product return, replacement, or repair.

      Warning (READ CAREFULLY BEFORE USE)
       ANSWatch-Mini should not be used on patients with severe cardiovascular diseases, poor blood circulation, or late-stage cancers. Always consult with your physician first.
       Press “Power” key to stop if the patient feels discomfort for any reason during a test. Promptly remove the device from the wrist if the device fails to pump or to release air pressure.
       If an “error” message appears on the screen of connected devices (smart phone, tablet, or PC) during a test, follow the instructions on the screen. If conducting a second test is needed, wait for 10-15 minutes. If error messages keep appearing, notify your sales representative immediately. Consultation with your physician is also recommended. *It is noted that patients with weak pulses or very large wrists (although few) may not be suitable for ANSWatch tests.
       During or after a test, if severe skin color change is observed, stop the test. Promptly remove the device from the wrist if the device fails to pump or to release air pressure. *Do not use the device again. Notify your sales representative immediately. Consultation with your physician is also recommended.
       Do not unscrew or open the product outer box (product warranty is nullified if the outer box is opened); Do not modify the product.
    • Instructions for Use
    • Visit the developer site
    Copyright
    • © Taiwanscientific