Electrical Calc Elite
NEC Code Calculator
$19.99 · In‑App Purchases · Designed for iPad. Not verified for macOS.
Buy once, own it — no subscription. Every table, correction factor and code citation follows the NEC® edition you pick. Works offline, with no ads and no account.
Electrical Calc Elite™ is the electrician's code calculator that follows the NEC® edition your inspector enforces. Size wire, check voltage drop, fill conduit and size motor circuits — offline, in seconds. Answers that come from a code table print which one. One purchase, no subscription.
Ten editions of the National Electrical Code® are built in — NEC® 2026*, 2023, 2020, 2017, 2014, 2011, 2008, 2005, 2002 and 1999 — and every table, correction factor and code reference follows the one you select.
BUILT FOR
Electricians, contractors, estimators, engineers, maintenance techs, inspectors, apprentices studying for the exam, and homeowners checking their work.
WIRE SIZE AND AMPACITY
• Required wire size in AWG or kcmil from amps: copper or aluminum, single-phase or three-phase, 60/75/90°C insulation, at 100% or 125%
• Ampacity in raceway or free air, from the NEC® ampacity tables (310.16 and 310.17, or the earlier equivalents)
• Ambient temperature correction above or below 30°C, in °C or °F
• Adjustment for more than three current-carrying conductors in a raceway
• Parallel and derated conductor sizing
• Circular mils and kcmil for any wire size
VOLTAGE DROP
• Volts and percent dropped from one-way length, amps, phase and wire size, with Chapter 9 Table 8 resistance corrected to 60, 75 or 90°C
• Wire size for a long run, flagged VD WIRE SIZE when the drop, not the ampacity table, set it
• Longest one-way run a wire size will carry inside your limit: 3% by default, or any limit you set
• 1- or 3-phase, copper or aluminum, feet or meters; wire resistance per 1000 ft on its own key
CONDUIT SIZING AND FILL
• 12 conduit types: EMT, ENT, FMC, IMC, LFNA, LFNB, LFMC, RMC, PVC schedule 40 and 80, Type A and Type EB
• Trade size for a mix of THW/THHW, XHH/XHHW or THHN/THWN conductors
• Fill percentage, cross-sectional area and area remaining, from the Chapter 9 tables, with the correct 1-, 2- and over-2-wire fill limits
• Maximum conductors of a given size a conduit will take
MOTORS
• Full-load current for 1-phase, 3-phase, synchronous and DC motors, from NEC® Tables 430.247, 430.248 and 430.250
• Horsepower from amps, and full-load amps from horsepower
• Maximum fuse and breaker size from Table 430.52 (430.52(C)(1) in 2023 and 2026) — single-element or dual-element fuse, inverse-time or instantaneous-trip breaker, across seven motor types
• Motor overload protection per 430.32(A)(1)
• NEMA starter size, per NEMA ICS 2
GROUNDING
• Equipment grounding conductor size, per 250.122
• Grounding electrode conductor size, per 250.66
POWER, MATH AND CONVERSIONS
• Convert between amps, watts, volts, VA, kVA, kW, power factor %, efficiency % and DC resistance
• Ohm's Law: enter any two of ohms, volts or amps to get the third
• Kirchhoff's Law
• Parallel resistance
• BTU ↔ kilowatt-hours
• Doubles as a standard calculator, with Store and Recall memory keys
CODE REFERENCES YOU CAN CHECK
Wire size, fuse, breaker, overload and grounding answers print the table or section they came from, numbered as your selected edition numbers it. Fuse and breaker cards show the percentage of full-load current used and the current it was applied to.
HELP BUILT IN
Hold any function key to open the manual at that key's own section. A Help key opens it from the front, with worked keystroke examples. A Getting Started guide and the full manual are included.
WORKS OFFLINE
Every calculation runs on the device. No account, no sign-in, no ads, and no waiting on a signal in a basement or a mechanical room.
SUPPORT
Free technical support
techsupport@cyberprodigy.com — https://www.cyberprodigy.com/contact.html
Manual: https://www.cyberprodigy.com/electricalcalcelite/
*NEC® 2026 code data is a one-time in-app purchase. The other nine editions are included.
Electrical Calc Elite™ is not associated with ElectriCalc® Pro and Cyberprodigy LLC is not affiliated with Calculated Industries, Inc.
- Added: One-time in-app purchase option for NEC® 2026 code additions
- Added: fuse and breaker results name the next standard size NEC® 240.6(A) allows
- Ambient temperatures outside your edition's correction table are flagged
- Wire sizing extended: NEC® 240.4(D) small-conductor limits and the Code minimum conductor size
- Conduit fill extended: the NEC® Chapter 9 Note 7 round-up
- Redesigned Preferences, pickers and dialogs
- Hold any function key to open the manual at that key's own section
- Compatibility updates for current iOS versions
The developer, Cyberprodigy LLC, indicated that the app’s privacy practices may include handling of data as described below. For more information, see the developer’s privacy policy .
Data Not Collected
The developer does not collect any data from this app.
Accessibility
The developer has not yet indicated which accessibility features this app supports. Learn More
Information
- Seller
- Cyberprodigy LLC
- Size
- 6.2 MB
- Category
- Utilities
- Compatibility
Requires iOS 15.6 or later.
- iPhone
Requires iOS 15.6 or later. - iPad
Requires iPadOS 15.6 or later. - iPod touch
Requires iOS 15.6 or later. - Mac
Requires macOS 12.5 or later and a Mac with Apple M1 chip or later.
- iPhone
- Languages
- English
- Age Rating
4+
- 4+
- In-App Purchases
Yes
- NEC 2026 Code Additions $5.99
- NEC 2023 Code Additions $4.99
- Copyright
- © Cyberprodigy LLC
