neoSim by Nicutools is an interactive neonatal resuscitation simulator designed for medical students, nurses, midwives, and doctors who want to build and maintain their resuscitation skills outside of the clinical environment.
The simulator models realistic newborn physiology — heart rate, oxygen saturation, temperature, and lung mechanics all respond dynamically to your interventions. There is no script: the baby responds to what you do, and to what you fail to do.
MODES
Tutor — guided coaching with real-time feedback on common errors like inadequate ventilation rate, inappropriate FiO2, slow compression rate, inadequate thermal control
Practice — unguided free practice with full equipment access. Develop fluency and muscle memory and get comprehensive debrief with score.
Challenge — a random scenario scored against a checklist covering seven domains: preparation, ventilation, circulatory support, de-escalation, oxygen management and thermoregulation
SCENARIOS
Term scenarios span mild, moderate, and severe birth asphyxia, antepartum haemorrhage, pneumothorax, sepsis. Preterm scenarios cover infants from 24 to 34 weeks gestation, with lung mechanics and resuscitation thresholds adjusted for gestational age. The manikin proportions scale continuously across the full 24-42 week range. Each scenario generates a unique patient with randomised starting parameters.
Sim Builder lets you design, test, play and share your own custom sims: you set GA and weight, antenatal history, lung disease, starting vitals, cord lactate, Hb and more. You can pre-set a range of initial PIP and PEEP and Flow and FiO2 settings to teach careful equipment set up pre-birth.
EQUIPMENT
Mask ventilation with real-time manometer (PIP and PEEP), endotracheal intubation, umbilical venous catheter with animated insertion, adrenaline and fluid bolus administration, needle decompression for tension pneumothorax, surfactant, supplemental oxygen with blender control (FiO2 21-100%), overhead heater, plastic wrap, and hat.
SCORING
Full post-simulation debrief with breakdown across multiple domains. Category scores highlight specific gaps.
neoSim is informed by NRP and ANZCOR neonatal resuscitation guidelines. It is an educational tool intended to supplement, not replace, formal training and clinical supervision. neoSim is not a medical device and must not be used for clinical decision-making or patient care.
more A NEW 3D MANIKIN
The manikin is now a full-body 3D newborn. Muscle tone follows the infant's respiratory drive: a vigorous baby holds a flexed posture, moves its limbs, opens and closes its hands and looks around; a compromised baby lies limp with closed eyes. The chest rises with each inflation, recession and
tracheal tug appear with respiratory distress, and the sternum depresses under compressions. Skin colour follows oxygenation and perfusion, and the baby appears wet until dried (and cools quickly unless dried)
Manikin body habitus reflects the weight for gestational age.
All procedures and equipment are now shown on the 3D newborn.
RESUSCITAIRE
The controls are laid out as a modern resuscitaire: a T-piece manometer, O₂ and flow knobs, a PIP knob, and a PEEP valve you turn on the T-piece itself. Gas settings can be adjusted before birth. Delivered PEEP now depends on flow, as on a real T-piece: the PEEP valve setting is the pressure it gives at 10 L/min.
IPAD
Sims now fill the iPad screen, with text and controls enlarged to match.
PHYSIOLOGY
Circuit compliance and leak are modelled: leak rises with airway pressure, and nasal CPAP and nasal ventilation leak through the open mouth.
Low PEEP lets alveoli collapse at end-expiration, reducing compliance.
Bolus delivery time scales with the dose, so the infusion rate is constant.
Capillary refill can be assessed by pressing on the manikin's "skin"
SCORING
Various improvements to sim scoring
A partly delivered LISA dose earns credit for what was given.
OTHER CHANGES
Haptic clicks on the PEEP valve and the oxygen cylinder's flow selector.
Sim Builder: a full-screen vignette editor, a mask-leak setting, and vignettes that quote an estimated fetal weight.
The tutorial mode updated
A range of minor interface improvements.
2.9.0 Oct 16
SCORING
The debrief now scores what the baby needed rather than what was attempted. An intervention that was indicated but not delivered counts against the score instead of being left out of it — previously, skipping something could score better than doing it imperfectly.
Ventilation, chest compressions and adrenaline are treated as critical actions. Not delivering one when it was indicated caps the overall score, and the debrief states which action it was and the time it became indicated.
Unnecessary adrenaline, compressions, UVC insertion, intubation and needle decompression are now grouped as safety events rather than sitting among the checklist items.
Earlier scores are unchanged and remain in the training log. Sim of the Day percentiles are compared within a scoring version, so earlier scores are not
ranked against the new ones.
SELF-INFLATING BAG
Sims can now be authored with a self-inflating bag in place of a T-piece resuscitator. Inflations are delivered by squeezing the bag; rate, depth and
inspiratory time reflect the squeeze. The pressure-relief valve is set at 35 cmH₂O and can be held shut where higher pressures are required. The bag delivers no PEEP.
An oxygen reservoir can be fitted and removed during the sim. Reservoir fill is integrated from delivered flow and modulates delivered FiO₂ below the source gas.
Delivered FiO₂ from the bag is derived from published bench measurements in neonatal self-inflating bags (Sasi et al., J Paediatr Child Health 2013). On 100% source gas without a reservoir it is approximately 75% at 1 L/min and plateaus near 94%; the commonly taught 40% is reached only at about 0.2 L/min (which cannot be delivered on the installed flow meter)
Fixed bug where the chest did not move during bag inflations. Delivered tidal volume, scoring and the infant's response were correct throughout — only the chest movement was missing, so effective ventilation could read as ineffective.
OXYGEN CYLINDER SUPPLY
Gas supply is authored independently of the device, so either a T-piece or a bag may run on blended gas or on a cylinder. Where a cylinder is used there is no blender and flow rate is the only oxygen control: contents deplete with use, delivered flow tapers below 20 bar, and a spent cylinder can be exchanged mid-sim.
TRANSILLUMINATION
The cold light glow is smaller, brighter and less red, so it reads against well-perfused skin rather than only against a cyanosed chest. Saturated red is
now reserved for the affected hemithorax under tension pneumothorax, widening the contrast between sides.
Fixed bug where transillumination wand disappeared behind the chest.
OTHER CHANGES
- Laryngeal mask (i-gel) insertion is animated through the full placement sequence.
- Subcostal recession intensity scales with central respiratory effort, not chest wall movement alone.
- Reduced chest excursion for normal spontaneous breathing.
- Solo sims no longer end early while a pneumothorax is being assessed with the cold light.
- Shared sim links can be set to last up to six months and have no limit on the number of plays. An expired link now names the sim and who sent it.
2.8.2 Aug 24
SELF-INFLATING BAG
Sims can now be authored with a self-inflating bag in place of a T-piece resuscitator.
Inflations are delivered by squeezing the bag; rate, depth and inspiratory time reflect the
squeeze. The pressure-relief valve is set at 35 cmH₂O and can be held shut where higher
pressures are required. The bag delivers no PEEP.
An oxygen reservoir can be fitted and removed during the sim. Reservoir fill is integrated
from delivered flow and modulates delivered FiO₂ below the source gas.
Delivered FiO₂ from the bag is derived from published bench measurements in neonatal
self-inflating bags (Sasi et al., J Paediatr Child Health 2013). On 100% source gas without
a reservoir it is approximately 75% at 1 L/min and plateaus near 94%; the commonly taught
40% is reached only at about 0.2 L/min (which cannot be delivered on the installed flow meter)
OXYGEN CYLINDER SUPPLY
Gas supply is authored independently of the device, so either a T-piece or a bag may run on
blended gas or on a cylinder. Where a cylinder is used there is no blender and flow rate
is the only oxygen control: contents deplete with use, delivered flow tapers below 20 bar,
and a spent cylinder can be exchanged mid-sim.
TRANSILLUMINATION
The cold light glow is smaller, brighter and less red, so it reads against well-perfused
skin rather than only against a cyanosed chest. Saturated red is now reserved for the
affected hemithorax under tension pneumothorax, widening the contrast between sides.
Fixed bug where transillumination wand disappeared behind the chest.
OTHER CHANGES
- Laryngeal mask (i-gel) insertion is animated through the full placement sequence.
- Subcostal recession intensity scales with central respiratory effort, not chest wall
movement alone.
- Reduced chest excursion for normal spontaneous breathing.
- Solo sims no longer end early while a pneumothorax is being assessed with the cold light.
2.8.1 Aug 23
SELF-INFLATING BAG
Sims can now be authored with a self-inflating bag in place of a T-piece resuscitator. Inflations are
delivered by squeezing the bag; rate, depth and inspiratory time reflect the squeeze. The pressure-relief
valve is set at 35 cmH₂O and can be held shut where higher pressures are required. The bag delivers no PEEP.
An oxygen reservoir can be fitted and removed during the sim. Reservoir fill is integrated from delivered
flow and modulates delivered FiO₂ below the source gas.
Delivered FiO₂ from the bag is derived from published bench measurements in neonatal self-inflating bags
(Sasi et al., J Paediatr Child Health 2013). On 100% source gas without a reservoir it is approximately 75%
at 1 L/min and plateaus near 94%; the commonly taught 40% is reached only at about 0.2 L/min.
OXYGEN CYLINDER SUPPLY
Gas supply is authored independently of the device, so either a T-piece or a bag may run on blended gas or on
a cylinder. Where a cylinder is used there is no blender and flow rate is the only oxygen control: contents
deplete with use, delivered flow tapers below 20 bar, and a spent cylinder can be exchanged mid-sim.
OTHER CHANGES
- Laryngeal mask (i-gel) insertion is animated through the full placement sequence.
- Subcostal recession intensity scales with central respiratory effort, not chest wall movement alone.
- Reduced chest excursion for normal spontaneous breathing.
2.8.0 Aug 20
The 2.7 series brings neoSim's biggest visual upgrade yet, plus more realistic
physiology.
A new 3D chest
• A true 3D torso replaces the flat manikin — lifelike chest rise, indrawing and colour change.
• "Cold Light" transillumination now shines applied via a "wand" not your finger-tip for better visibility, with the
affected side glowing red under a tension pneumothorax.
Smarter thermoregulation
• Plastic wrap now properly keeps preterm babies warm — and is offered for any baby under 1500 g.
• Cold babies now show depressed breathing (apnoea when severe), reversing on rewarming.
• Overheating now behaves realistically by gestation.
2.7.2 Jul 30
• Meet the new 3D newborn — a fully three-dimensional chest that rises, retracts and changes colour in real time, so every breath, compression and intervention feels true to life.
• Cold Light transillumination now uses a handheld wand — your finger no longer blocks the glow when localising a pneumothorax, with cleaner, more realistic light.
• Tension pneumothorax — the affected side now shows subtle chest movement and indrawing instead of sitting frozen, recovering as you decompress.
• Refined scoring for chest-compression response.
• Stability and polish.
2.7.1 Jul 29
Meet the new 3D ventilation sim model!
A sculpted, shaded 3D newborn that breathes with your ventilation — cyanosis, subcostal recession and chest asymmetry rendered live
More realistic chest-rise and lung mechanics, including over-bagging and true expiratory timing
3D transilluminate to diagnose a tension pneumothorax, then needle-decompress
New respiratory-effort control when you build your own sims
Your CPD training log now restores your name and achievement tiers automatically after reinstalling or signing in on a new device
Numerous realism, scoring and stability improvements3D chest — the baby's chest is now a detailed 3D model, with more lifelike breathing and clearer clinical signs: chest rise, subcostal/intercostal recession, and pneumothorax findings all read more realistically. Prefer the classic look, or on an older device? Settings → Display → 3D chest switches back to the 2D view.
More realistic fluid physiology — over-transfusion now reflects circulatory overload, with pulmonary oedema worsening oxygenation.
Airway fix — fixed a bug exposed if nCPAP commenced during intubation attempt
Polish — smoother transillumination when checking for pneumothorax, a corrected UVC catheter tip position, and refined pneumothorax chest signs.
2.7.0 Jul 26
Nasal CPAP: choose nasal CPAP for preterm RDS instead of mask PPV. Available for babies ≤32 weeks.
LISA (Less Invasive Surfactant Administration): give surfactant via thin catheter without intubating. Tap Surfactant with no ETT in place to start
LISA; with an ETT in, it gives the INSURE dose.
Ability to bail out of LISA if infant unstable
Failed intubation: pick a tube that's too large for the baby and you'll now see the attempt play through: blade in, tube enters, tube withdraws,
advisory across the top.
Code button: bell glyph plus a clearer red-to-green colour change when help has been called.
Vagal HR drop while the laryngoscope blade is in the airway.
2.6.0 Jun 23
Sim Builder — refinements
Sim Builder (the Design & Share Your Own Sims feature added in 2.5.0) lets you author and share custom resuscitation scenarios. Three fidelity issues
are resolved this release.
Custom sims with high airway obstruction now actually obstruct ventilation as authored — previously, even setting obstruction to 100 % silently rolled through to zero. Meconium aspirate is now clearly visible during suction: the catheter darkens to a near-black column as you suction, with intensity scaled to the obstruction level. And the PPHN checkbox now produces clinically visible PPHN behaviour at any lactate — previously it had no effect on babies authored at modest lactate. A well term baby with PPHN at lactate 2 now reads as the classic teaching presentation: SpO₂ around 88 % on room air, climbing to ~97 % on 30 % O₂
Newborn breathing patterns: Babies described as breathing regularly at birth no longer appear apnoeic on arrival at the warmer. The brainstem drive model has been retuned so that a well term baby in the transitional first-minute window — typical SpO₂ in the 50s, mild lactate — visibly breathes rather than presenting at the borderline of apnoea. Extreme preterms without asphyxia continue to present with the expected immature pattern — apnoea or minimal respiratory effort at the same saturations. Gasping, when it occurs, now reads as a depressed-but-visible pattern (6–20 /min) rather than once-every-15-seconds.
Early-sim fairness floor
In the first 3 minutes, a competent NRP-style resuscitation now has a soft floor on SpO₂ so the engine's feedback loops can't compound into a non-survivable state when the team is doing the right thing. The floor activates only when ventilation is effective, FiO₂ is fully escalated, and if HR is below 60) compressions are running. Fades out before the 3-minute mark so the underlying physiology asserts after the resuscitation window.
Stability
Several quieter fixes including a refactor that closes a class of parity bugs between iOS and the engine, an Xcode build script that self-heals on machines without node in the default path, and tighter tuning across the meconium suction animation on both iOS and the web team mode.
2.5.1 Jun 7
Design and share your own sims
You can now author custom resuscitation cases from scratch. Tap "Design & Share Your Own Sims" on the home screen to set gestation, weight, severity,
antenatal history, equipment startup state and more, then test your case before saving.
A Saved Sims list lets you revisit, rename, duplicate, edit, or delete anything you've authored. From the same list, tap Share to generate a link your colleagues can open in any browser — no app or account needed on their end. Set play caps (up to 40) and expiry (up to 14 days), and override the title shown to recipients if your working name isn't what you want them to see.
Recipients get a short preview page with the case vignette before they tap Play.
Asymmetric pneumothorax visuals
Pneumothorax scenarios now show asymmetric subcostal indrawing — the healthy side does the extra work and the affected side stays quiet,
matching real-world clinical signs. The transilluminator glow fades smoothly across the midline and the diaphragm rather than stopping at a sharp line.
Live pre-warmer banner for authored sims
For sims you've designed, the banner across the pre-warmer / cord-clamp window updates with live engine state — tone, breathing, and pallor reflect physiology as the case evolves toward warmer arrival.
Stability + scoring
Several fixes to saved-sim playback (including older records without form state), share-link reliability, and edge-case scoring for cord clamp and
flow rate.
2.5.0 Jun 6
Share sims with colleagues or trainees via secure browser links (capped by play count + expiry; sign-in required to create).
Restored intended airway-obstruction profile for built-in MAS scenarios (was silently disabled on iOS).
Esophageal intubation: placement recognition, scoring, re-intubation flow.
T-piece physics: more accurate tidal volume and mean airway pressure under leak.
ETT adrenaline pathway: animation + route-aware pharmacology.
PEEP range widened to 0–20 cmH₂O with quadratic pneumothorax risk above 5.
AI debrief not offered when your device is offline.
Numerous smaller engine and UI refinements.
2.4.0 May 29
Three-tier credentials — Earn Code Team, Advanced, and Specialist badges as you master scenarios. Your debrief now shows exactly what's left for the next tier.
Esophageal intubation recognition — ETTs can land in the esophagus, just like in real life. Spot the signs — no chest rise, no CO₂ — and reposition. A new scoring item rewards fast recognition.
ETT size matters — Pick the wrong size and you'll fail to intubate. Right-sized tubes seal better.
ETT adrenaline route — Give adrenaline down the ETT when there's no umbilical access. The engine models slower, less reliable absorption.
Better chest recession animation
Refined T-piece physics — Manometer shows the realistic peak pressure actually being delivered under leak. PEEP range widened
Polish — Surfactant administration with proper T-piece detachment, clearer cord clamp message, ELBW transilluminator tuning, fairer airway scoring, and many smaller refinements.
2.3.4 May 19
Bug fix
Improved accuracy of post-transfusion Hb
2.3.3 May 14
More accurate ventilation modelling
2.3.2 May 13
Refined pneumothorax trigger physiology
Improved chest rise accuracy across weight ranges
Minor UI improvement
Various engine tuning improvements
2.3.1 May 12
Improved iPad support with adaptive layout and docked advanced equipment panel. Improved readability on smaller screens.
2.3 May 11
Mean airway pressure now drives oxygenation — PIP, PEEP, and Ti combinations affect SpO2 more realistically
Esophageal intubation can occur on ~5% of ETT attempts — recognise via no chest rise, falling SpO2, no CO2 detection
Refined RDS, MAS, and ELBW preterm physiology to match clinical trajectories more closely
Minor scoring fix for initial FiO2 selection
Subcostal recession fix
Flow meter track and manometer rise speed fixes
2.2 May 11
Set up heater, FiO2, PIP, PEEP and flow before the baby arrives — matches real NRP workflow
Pulse-oximeter beep with adjustable volume
Tutorial: clearer pacing with blocking helper modals before each step
Refined AI debrief tone and length
Fixed extubation, suction, and surfactant animations
2.1 May 9
A NEW 3D MANIKIN
The manikin is now a full-body 3D newborn. Muscle tone follows the infant's respiratory drive: a vigorous baby holds a flexed posture, moves its limbs, opens and closes its hands and looks around; a compromised baby lies limp with closed eyes. The chest rises with each inflation, recession and
tracheal tug appear with respiratory distress, and the sternum depresses under compressions. Skin colour follows oxygenation and perfusion, and the baby appears wet until dried (and cools quickly unless dried)
Manikin body habitus reflects the weight for gestational age.
All procedures and equipment are now shown on the 3D newborn.
RESUSCITAIRE
The controls are laid out as a modern resuscitaire: a T-piece manometer, O₂ and flow knobs, a PIP knob, and a PEEP valve you turn on the T-piece itself. Gas settings can be adjusted before birth. Delivered PEEP now depends on flow, as on a real T-piece: the PEEP valve setting is the pressure it gives at 10 L/min.
IPAD
Sims now fill the iPad screen, with text and controls enlarged to match.
PHYSIOLOGY
Circuit compliance and leak are modelled: leak rises with airway pressure, and nasal CPAP and nasal ventilation leak through the open mouth.
Low PEEP lets alveoli collapse at end-expiration, reducing compliance.
Bolus delivery time scales with the dose, so the infusion rate is constant.
Capillary refill can be assessed by pressing on the manikin's "skin"
SCORING
Various improvements to sim scoring
A partly delivered LISA dose earns credit for what was given.
OTHER CHANGES
Haptic clicks on the PEEP valve and the oxygen cylinder's flow selector.
Sim Builder: a full-screen vignette editor, a mask-leak setting, and vignettes that quote an estimated fetal weight.
The tutorial mode updated
A range of minor interface improvements.