Corsano
Continuous Health Monitoring
Free · Designed for iPad. Not verified for macOS.
The Corsano CardioWatch 287-2 System is a Remote-Patient Monitoring System that consists of a monitoring bracelet device worn on the wrist by adult patients (aged 22 years old and over), a web-based browser platform and a user mobile application operable in either Patient Mode or Healthcare Practitioner (HCP) Mode.
Vital signs data both on mobile devices and web-based dashboard are available to the HealthCare Provider.
The bracelet is intended to continuously monitor physiological vital sign data (Pulse Rate, oxygen saturation, temperature and activity levels, and for intermittent monitoring of respiratory rate from the person being monitored and securely transmit the encrypted data via the Patient App to the secure server.
The bracelet is intended for use in professional healthcare facilities, such as hospitals or skilled nursing facilities, or the home under supervision by trained healthcare professionals.
The Healthcare Practitioner can securely access the patient physiological signs remotely via the mobile application HCP Mode or via a browser web-interface which are also intended to provide visual and audible physiologic multi-parameter alarms.
You can share your data with Apple Health such as steps, sleep, pulse rate...
You can manage Apple Health settings in the Apple Health App and turn on writing of step, sleep, and heart rate analysis.
This application is intended to support, not replace, the clinical judgment of qualified healthcare professionals. The information provided by this app must not be used as the sole basis for any diagnosis, treatment decision, or medical intervention. Users should always seek advice from a licensed physician or other qualified healthcare provider in addition to using this application, and prior to making any medical decisions. In case of symptoms, concerns, or abnormal readings, consult a healthcare professional immediately.
Ratings & Reviews
Patch: Minor UI improvements
The developer, Corsano Health B.V, indicated that the app’s privacy practices may include handling of data as described below. For more information, see the developer’s privacy policy .
Data Not Collected
The developer does not collect any data from this app.
Accessibility
The developer has not yet indicated which accessibility features this app supports. Learn More
Information
- Size
- 467.9 MB
- Category
- Health & Fitness
- Compatibility
Requires iOS 15 or later.
- iPhone
Requires iOS 15 or later. - iPad
Requires iPadOS 15 or later. - iPod touch
Requires iOS 15 or later. - Mac
Requires macOS 12.0 or later and a Mac with Apple M1 chip or later. - Apple Vision
Requires visionOS 1.0 or later.
- iPhone
- Location
- This app may use your location even when it is not open, which can decrease device battery life.
- Languages
English and 15 more
- English, Arabic, Danish, Dutch, Finnish, French, Georgian, German, Greek, Hebrew, Italian, Norwegian Bokmål, Polish, Portuguese, Spanish, Swedish
- Age Rating
9+
- 9+
- Contains
Health or Wellness Topics
- Provider
Corsano Health B.V
- Corsano Health B.V has identified itself as a trader for this app and confirmed that this product or service complies with European Union law.
- DUNS Number
493148003 - Address
Waldorpstraat 5 The Hague Tech 's
2521 CA Gravenhage
Netherlands - Phone Number
+41 789234697 - Email
mburel@mmt.ch
- Medical Device
Yes
- Corsano Health B.V indicated this app is a regulated medical device and complies with European Union law.
- The information below has not been verified by Apple.
- Manufacturer SRN
- NL-MF-000013825
- Address
- Waldorpstraat 5 The Hague Tech 's
2521 CA Gravenhage
Netherlands - Phone Number
- +41 78 923 46 97
- Email Address
- mburel@mmt.ch
- Use Statement
- The CardioWatch 287-2 System is a wireless remote monitoring intended for continuous collection of physiological data in home and healthcare settings. This includes heart rate, heart rate variability (R-R interval), respiration rate, activity, sleep, ECG, SpO2, Body Temperature and Blood Pressure. Data is transmitted wirelessly from the device via the application or gateway to a server or health cloud where it is stored and made available for further analysis. The CardioWatch 287-2 System is intended for atrial fibrillation screening. The CardioWatch 287-2 System is intended to provide visual and audible physiologic multi-parameter alarms. The CardioWatch 287-2 System is not intended for high-acuity environment.
- Safety Information
- These situations could result in serious injury or damage if not avoided:
Patient & Clinical Limitations
• For use by qualified medical personnel only, always under Healthcare Practitioner supervision
• Not intended for high-acuity environments such as ICUs or operating rooms
• Not for use on acutely ill cardiac patients at risk of life-threatening arrhythmias (e.g., very fast atrial fibrillation) — a continuous ECG monitor should be used instead; this device is not a substitute
• Consult your Healthcare Practitioner before use if you have arrhythmias, arterial sclerosis, poor perfusion, diabetes, pregnancy, pre-eclampsia, or renal disease
• Never diagnose or treat yourself based on readings from this device
• Never adjust medication based on device readings — only a physician can do this
• Intended for a single patient only — do not use on another person during monitoring
Medical Procedures & Environments
• Remove the bracelet before patient defibrillation
• Do not use in areas with high-frequency (HF) surgical equipment, hyperbaric chambers, or CT scanners
• Do not use near strong electromagnetic fields (e.g., anti-theft systems, metal detectors)
• Do not use in oxygen-rich environments (>25% concentration) or near flammable gas
• This bracelet is MR-unsafe — do not expose it to any MRI environment; it may cause projectile injury, thermal burns, image artefacts, or device malfunction
Population Restrictions
• Do not use on infants, toddlers, children, or persons unable to express themselves (not validated in pediatric populations)
• Do not use on an injured arm or one in use for other medical treatment (e.g., dialysis shunt)
• Do not use if you have severe blood flow problems, blood disorders, or damaged/irritated skin
Device & Electrical Safety
• Do not use with other medical electrical equipment simultaneously unless authorised by Corsano
• Never allow the bracelet or mobile phone to fully discharge
• Never plug/unplug the charger with wet hands
• Inspect all cables before use; never use cracked, worn, or damaged cables
• No modifications to the bracelet are permitted — these may cause electric shock, burns, or death
• If a serious incident occurs related to the device, it must be reported to Corsano Health and the relevant Competent Authority in your country
- Instructions for Use
- Visit the developer site
- Copyright
- Copyright © 2026 Corsano Health B.V.