VirtualCSP

Istruzione

Gratis · Progettata per iPad

Developed for healthcare professionals who want to be trained on conduction system pacing using the Medtronic SelectSecure 3830 lead. The course consists of structured tutorials organised in chapters and knowledge check with score report. All content is based on interactive real-time 3D heart simulation. All text is available in English and French. Use of Apple Pencil or a soft rubber tip pen is recommended for better interaction. This app executes in landscape mode only. TRAINING OBJECTIVES Pacing lead 3830 placement with selective, non-selective, anodal, or myocardium pacing. Perform unipolar tip, unipolar ring and bipolar pacing. Obtain live 12-lead ECG and intra-cardiac signals from pacing lead. Observe ECG changes with different outputs and during lead progression. Observe current of injury changes during lead progression. Take intrinsic and paced QRS measurements. Take potential - V measurements. Take paced V6RWPT and V6-V1 inter-peak interval measurements. Perform threshold test. Observe patient cases LBBB, RBBB. GUI FEATURES Main menu Guide Chapters Conduction system anatomy Conduction system pacing Types of capture Measurements Transitions LBBAP algorithm Observations during implant Getting to know the tools Knowledge check Disclosures Additional features Preset lead positions: HB proximal, HB distal, LBB, LAF, LPF, RBB, LVS close to LBB and LVS further from LBB. Manual interactive pacing lead insertion. Types of capture: selective, non-selective, anodal, myocardium. Pacing controls: pace on/off, pulse rate (30-200ppm), output (0.1-15V). Pacing lead polarity: unipolar tip, unipolar ring, bipolar. Patient cases: left bundle branch block, right bundle branch block, normal rhythm Views: 3D transparent, fluoroscopy, close-up view ADDITIONAL FEATURES App rate and review Settings: General app settings: sounds on/off, action point indices on/off, tool tips on/off, self-study / tutor mode switch. Anatomical views: atria on/off, ventricles on/off, cross-section view, transparent - b/w - color view, valves on/off, preset camera views. Simulation speed: slow motion, standard (Hi-Fi) speed (recommended). Intrinsic heart rate parameters (available in tutor mode) DCCV 12-lead ECG / single lead ECG view 3D heart view: You can change the heart view by dragging your mouse, pad or finger on the screen. You can also use the RAO-LAO slider at the bottom of the screen to alter the horizontal viewing angle. Live ECG window: Displays the 12-lead ECG and two CSP (EGM) signals, filtered CSP signal (cyan), unfiltered signal with current of injury (COI) (green). You can resize the ECG window by dragging the yellow dot at the top left of the ECG window. You can pause the simulation by tapping anywhere on the live ECG window, or on the pause/play button at the top-right corner. Tap again to resume the simulation. When paused, you can use the caliper tool to take measurements in ms or bpm. You can add up to 5 caliper segments. When paused, a slider at the bottom of the ECG window, allows you to scroll the ECG back and forth and see the ECG waves in parallel with the action potential wavefront on the 3D heart view (in 3D transparent view). You can also scroll the simulation by dragging your mouse or pad left/right on the paused ECG window. The snapshot tool allows you to create an ECG snapshot in a pop-up window. Useful when you want to compare transition morphologies on the ECG. © 2025 Medtronic, Inc. Powered by Epicardio Ltd.

  • L’app non ha ricevuto un numero sufficiente di valutazioni o recensioni per poter mostrare una panoramica.

All text is now available in French Ability to reset the knowledge check in tutor mode Corrected issue with questions Q1 and Q2 in Case 1

Lo sviluppatore, Epicardio Ltd, ha indicato che le procedure per la tutela della privacy dell’app potrebbero includere il trattamento dei dati descritto di seguito. Per scoprire di più, consulta l’informativa sulla privacy dello sviluppatore .

  • Dati non collegati a te

    I seguenti dati possono essere raccolti ma non vengono collegati alla tua identità:

    • Posizione
    • Identificativi
    • Dati sull’utilizzo
    • Diagnosi

Le procedure per la tutela della privacy potrebbero variare, ad esempio in base alle funzionalità che utilizzi o alla tua età. Scopri di più

Lo sviluppatore ha indicato che quest’app supporta le seguenti funzioni di accessibilità. Scopri di più

  • Funzioni supportate

    • VoiceOver

    • Movimento ridotto

Dimensioni
  • 120,9 MB
Categoria
  • Istruzione
Compatibilità
Richiede iOS 15.6 o versioni successive.
  • iPhone
    Richiede iOS 15.6 o versioni successive.
  • iPad
    Richiede iPadOS 15.6 o versioni successive.
  • iPod touch
    Richiede iOS 15.6 o versioni successive.
  • Mac
    Richiede macOS 12.5 o versioni successive e un Mac con chip Apple M1 o versioni successive.
  • Apple Vision
    Richiede visionOS 1.0 o versioni successive.
Lingue
  • Inglese
Età
18+
Fornitore
Epicardio Ltd
  • Epicardio Ltd si identificata come operatore commerciale per questa app e ha confermato che il prodotto o il servizio è conforme alla legge dell’Unione europea.
  • Numero DUNS
    217206727
  • Indirizzo
    Flat 4
    13 Marlborough Road
    Richmond
    N/A
    TW10 6JT
    Regno Unito
  • Numero di telefono
    +44 7808403063
  • Email
    ios@epicardio.com
Copyright
  • © 2025 Medtronic, Inc.