REALITi

교육

무료 · iPad⁠용으로 디자인됨

iPad

REALITi is a new simulation ecosystem incorporating a realistic patient condition simulator and video review in a single system. Starting with 2 iPads, REALITi is a highly advanced patient monitor simulator which mimics proprietary monitors and defibrillators. By expanding the system with more iPads, a complete in-situ simulator can be created. Add REALITi Chart to use a simulated patient electronic medical record. Add REALITi Camera to incorporate live audio video streaming with vital sign display. Optionally stream via AirPlay to Apple TV. Instant video review once the simulation has ended is built into the system. Add REALITi Engage to allow observers to comment, vote and view media. Features: • Easy to use Dial and Button interface. • Over 75 ECG waveforms • Dynamic 12 lead ECG library. • Comprehensive Radiology image library with over 250 images. • Extensive and configurable laboratory results library. • Simulate ectopics, sinus arrhythmia, artefacts and interference on the ECG with ease. • Easy to use Checklist interface for simple student assessment. • Easy scenario creation with single screen scenario running and editing. • Many defibrillator and monitor screens included. • CPR Feedback • QCPR Screen ATLAS ALS Manikin compatible

  • 이 앱은 개요를 표시할 만큼 충분한 리뷰 또는 평가를 받지 않았습니다.

Atlas • Improved rhythm display accuracy on Atlas Junior and Baby by ignoring slight compressions (≤10 mm Junior, ≤6 mm Baby). • Resolved PSIMV mode issues: PSync now saves correctly, pInsp changes send properly, and switching PSync updates all controls. • Added ventilator settings to Scenario Events: parameters can be viewed, edited, and synced directly from event cards. Camera • Enhanced NIBP display and logging: values now appear in exported videos, redundant logs removed, and event labels simplified. Corpuls • Improved pacing display: C3 shows correct pacing lozenge; C1 applies continuous therapy with visible ‘STIM’ label. • Fixed Scenario Review Timeline for accurate playback. • Updated German translations: “Cancel” → “Abbr.”, “Demand” in uppercase, “Schrittmacher” → “Schrittm.” CPR Band / CPR Puck • Added Bluetooth signal strength (RSSI) logging to detect interference. • Logs now show “OK” or “Warning” based on signal stability. Hamilton T1 • Aligned Facilitator settings with Hamilton T1 parameters for consistent operation. • Adjusted ranges, increments, and validations for all key controls. • Improved spontaneous rate and I:E ratio interaction for stable timing. • Standby timer now starts only after a ventilation cycle. • Alarm settings retain correct values when switching modes or patient types. • Neonatal alarms reset to defaults and display valid limits. • Resolved overlapping Pressure Alarm dials to maintain proper top/bottom order. • Improved Trends tab and submenu behavior for smoother navigation. • Menus now close automatically when entering Standby. • Fixed I:E ratio display in SIMV+ and PSIMV+ modes. • Ventilation and ExpMinVol values display correctly with one decimal and retain settings after weight or alarm changes. • Adjusted PEEP/CPAP dial so max indicator appears only within valid range. • Patient type switching now resets values correctly; “Last Patient” retains defaults. • Resolved alarm dial overlaps for proper display order. Nihon Kohden – EMS1052 • Fixed CPR elapsed time reset and “Restart CPR” timing (now 10 s). • Improved Japanese Cardioversion messages with corrected layout and font. • Added suspend time messages: “Suspend 10s,” “20s,” and “Restart CPR 30s” appear during pauses and clear on resume. Scenarios • Added 100+ training scenarios: 73 Adult, 17 Paediatric, 13 Neonatal. • Organized under new folder structure; existing scenarios unchanged. Multiple Hardware • Fixed “No connected device” message display after disconnecting all devices. • Added automatic Bluetooth reconnection after unintended disconnects. • Manual disconnects remain user-controlled. • Renamed devices retain connections with consistent log updates. Multiple Screens • Fixed behavior when electrodes or pads are disconnected. • Heartbeat sounds and rate alarms now stay inactive until proper connection.

iSimulate Pty Ltd 개발자가 아래 설명된 데이터 처리 방식이 앱의 개인정보 처리방침에 포함되어 있을 수 있다고 표시했습니다. 자세한 내용은 개발자의 개인정보 처리방침 을 참조하십시오.

  • 사용자에게 연결된 데이터

    다음 데이터가 수집되어 신원에 연결될 수 있습니다.

    • 진단

개인정보 처리방침은 사용하는 기능이나 사용자의 나이 등에 따라 달라질 수 있습니다. 더 알⁠아⁠보⁠기

개발자가 이 앱이 지원하는 손쉬운 사용 기능을 아직 등록하지 않았습니다. 더 알아보기

  • 제공자
    • iSimulate Pty Ltd
  • 크기
    • 1.1 GB
  • 카테고리
    • 교육
  • 호환성
    iPadOS 13.0 이상 필요
    • iPad
      iPadOS 13.0 이상 필요
    • Mac
      macOS 13.0.0 이상 및 Apple M1 칩 이상이 탑재된 Mac이 필요
    • Apple Vision
      visionOS 1.0 이상 필요
  • 언어
    한국어 외 23개
    • 한국어, Klingon, 네덜란드어, 덴마크어, 독일어, 러시아어, 루마니아어, 세르비아어, 스페인어, 슬로바키아어, 에스토니아어, 영어, 이탈리아어, 일본어, 중국어(간체), 중국어(번체), 체코어, 크로아티아어, 튀르키예어, 포르투갈어, 폴란드어, 프랑스어, 핀란드어, 헝가리어
  • 연령 등급
    15+
  • 저작권
    • © Copyright 2021 iSimulate. All Rights Reserved.