LinX M1

Medical

Free · Designed for iPhone. Not verified for macOS.

LinX M1 is an application available on your phone used to receive and display the glucose concentration value and remind when the blood glucose value exceeds the upper or lower limit of the preset blood glucose value. It also has system Settings and other functions to help users analyze and evaluate the glucose reading of the continuous glucose monitoring system and form a report. Measurements displayed on LinX M1 cannot be used for the diagnosis or screening of diabetes. The app is intended for informational use only and is not a substitute for professional medical advice. Always seek the advice of your doctor or other qualified health provider with any questions you may have regarding a medical condition. Note: The compatible medical hardware is certified and available for use in the following countries/regions: European Union (EU). Disclaimer: LinX M1 is designed to support, not replace, professional medical care. Always consult your doctor or a qualified healthcare provider before making any medical decisions based on the information provided by this app. The app and its developers are not responsible for any health-related outcomes resulting from the use of or reliance on the data displayed.

  • This app has not received enough ratings or reviews to display an overview.

The developer, Micro Tech Medical (Hangzhou) Co., LTD., indicated that the app’s privacy practices may include handling of data as described below. For more information, see the developer’s privacy policy .

  • Data Linked to You

    The following data may be collected and linked to your identity:

    • Contact Info
    • User Content
    • Identifiers
    • Diagnostics
  • Data Not Linked to You

    The following data may be collected but it is not linked to your identity:

    • Health & Fitness

Privacy practices may vary based, for example, on the features you use or your age. Learn More

The developer has not yet indicated which accessibility features this app supports. Learn More

Size
  • 107.2 MB
Category
  • Medical
Compatibility
Requires iOS 14.0 or later.
  • iPhone
    Requires iOS 14.0 or later.
  • iPod touch
    Requires iOS 14.0 or later.
  • Mac
    Requires macOS 11.0 or later and a Mac with Apple M1 chip or later.
  • Apple Vision
    Requires visionOS 1.0 or later.
  • Apple Watch
    Requires watchOS 10.0 or later.
Languages
English and 23 more
  • English, Arabic, Azerbaijani, Bosnian, Burmese, Dutch, Estonian, Finnish, French, German, Greek, Hungarian, Italian, Mongolian, Nepali, Polish, Portuguese, Russian, Serbian, Simplified Chinese, Spanish, Thai, Turkish, Vietnamese
Age Rating
4+
Provider
Micro Tech Medical (Hangzhou) Co., LTD.
  • Micro Tech Medical (Hangzhou) Co., LTD. has not identified itself as a trader for this app. If you are a consumer in the European Economic Area, consumer rights do not apply to agreements between you and the provider.
Medical Device
Yes
  • Micro Tech Medical (Hangzhou) Co., LTD. indicated this app is a regulated medical device and complies with European Union law.
  • The information below has not been verified by Apple.
  • Manufacturer SRN
  • CN-MF-000001157
  • Address
  • China Mainland
    Zhejiang
    Hangzhou
    4 F, Building 3, No. 9 Haishu Rd., Cangqian St., Yuhang Dist.,
    311121
  • Phone Number
  • +86 571 8856 6372
  • Email Address
  • app.dev@microtechmd.com
  • Use Statement
  • 2. Intended Purpose
    Continuous Glucose Monitoring System Sensor: When
    the Continuous Glucose Monitoring System Sensor is
    used together with compatible software application, it
    is intended to continuously measure the glucose in the
    interstitial fluid and is designed to replace fingerstick
    blood glucose (BG) testing for treatment decisions.
    Continuous Glucose Monitoring App (iOS/Android):
    When the Continuous Glucose Monitoring App is used
    together with compatible sensors, it is intended to continuously measure the glucose in the interstitial fluid
    and is designed to replace fingerstick blood glucose
    (BG) testing for treatment decisions.
  • Safety Information
  • 3. 1.4 Contraindications
    The Continuous Glucose Monitoring System must be
    removed prior to Magnetic Resonance Imaging (MRI).
    Don’t wear your CGM sensor for computed tomogra￾phy (CT) scan, or high-frequency electrical heat (dia￾thermy) treatment.
    Taking higher than the maximum dose of acetamino￾phen (e.g. > 1 gram every 6 hours in adults) may affect
    the CGMS readings and make them look higher than
    they really are.
    The CGM System was not evaluated for the following
    persons:
    • Pregnant women
    • Peritoneal dialysis patients
    4
    • Patients with implanted pacemakers
    • Patients with coagulation disorders or those taking
    anticoagulant drugs
    1.5 Warning
    • Don’t wear your CGM sensor for computed tomog￾raphy (CT) scan, or high-frequency electrical heat
    (diathermy) treatment.
    • Don’t wear your CGM while using electrocautery,
    electrosurgical units and diathermy equipment.
    • The CGM System was not evaluated for the Peri￾toneal dialysis patients, Patients with implanted
    pacemakers and Patients with coagulation disorders
    or those taking anticoagulant drugs. Before you use
    the DiaExpert System, review all the product instruc￾tions.
    • The CGMS should not be used by Patients who have
    diffuse subcutaneous nodules.
    • Before you use the DiaExpert System, review all the
    5
    product instructions.
    • The User’s Manual includes all safety information
    and instructions for use.
    • Talk to your health care professional about how you
    should use your Sensor glucose information to help
    manage your diabetes.
    • Failure to use the System according to the in￾struc-tions for use may result in you missing a se￾vere low blood glucose or high blood glucose event
    and/or making a treatment decision that may result
    in injury. If your glucose alarms and readings from
    the System do not match symptoms or expectations,
    use a fingerstick blood glucose value from a blood
    glucose meter to make diabetes treatment decisions.
    Seek medical attention when appropriate.
    • Use of this equipment adjacent to or stacked with
    other equipment should be avoided because it could
    result in improper operation. If such use is necessary,
    this equipment and the other equipment should be
    observed to verify that they are operating normally.
    • Use of accessories, transducers and cables other
    6
    than those specified or provided by the manufacturer
    of this equipment could result in increased electro￾magnetic emissions or decreased electromagnetic
    immunity of this equipment and result in improper
    operation.
    • PORTABLE RF communications equipment (in￾clud-ing peripherals such as antenna cables and
    external antennas) should be used no closer than 30
    cm (12 inches) to any part of the [GX-01E, GX-02E],
    including cables specified by the MANUFACTURER.
    Otherwise, degradation of the performance of this
    equipment could result.
    • After restarting your mobile device, always check
    that Bluetooth is switched on. If it’s turned off, please
    enable Bluetooth again to ensure real-time data
    transmission and notifications.
    • Avoid areas:
    1. With loose skin or without enough fat to avoid
    muscles and bones.
    7
    2. That may get bumped, pushed, or where pressure
    is applied while sleeping.
    3. Within 2 inches of infusion or injection site.
    4. Near waistband or with irritations, scarring, tattoos,
    or lots of hair.
    5. With moles or scars.
    • Android users, after enabling airplane mode, please
    double-check if Bluetooth is turned on. If it’s turned
    off, please enable Bluetooth again to ensure re￾al-time data transmission and notifications. iOS users
    don’t need to consider this for the time being.
    • This medical device has been specially designed to
    be used safely by laypeople without medical exper￾tise in a domestic environment.
    1.6 Precautions
    • No modifications to the Continuous Glucose Mon￾itoring System Sensor are allowed. Unauthorized
    8
    modification of the CGMS may cause the product to
    malfunction and become unusable.
    • Before using this product, you need to read the In￾struction Manual or be trained by a professional. No
    doctor’s prescription is required for use at home.
    • The CGMS contains many small parts that can be
    dangerous if swallowed.
    • During rapid changes in blood glucose (more than
    0.1 mmol/L per minute), glucose levels measured in
    interstitial fluid by the CGMS may not be the same
    as blood glucose levels. When blood glucose levels
    drop rapidly, the sensor may produce a higher read￾ing than the blood glucose level; Conversely, when
    blood glucose levels rise rapidly, the sensor may pro￾duce a lower reading than the blood glucose level.
    In these cases, the sensor’s reading is checked by a
    fingertip blood test using a glucose meter.
    • Severe dehydration or excessive loss of water may
    result in inaccurate results. When you suspect you
    are dehydrated, consult a health care professional
    immediately.
  • Instructions for Use
  • Visit the developer site
Copyright
  • © 2024 MicroTech Medical (Hangzhou) Co., Ltd.