corpuls simulation
Train how you fight for lives
Free
corpuls simulation - Train how you fight for lives
Previous training methods have focused on learning a technique through repetition. However, there is often a large gap between theoretical scenarios and the actual “fight” for a human life. With corpuls simulation we bring 100% realistic scenarios to your training.
Just as pilots training in a flight simulator are thrown surprise complications, lifesavers training with corpuls simulation have to overcome unforeseen situations.
This creates an incomparably realistic training situation. The result is a team that is optimally prepared for every scenario and therefore, a significantly better quality of care for the patient.
- Realistic parameters and curves
- Safe training
- Scenario editor
- Simulation consumables
- Original accessories
- Multiple languages available
- corpuls simulation COMMUNITY
- Bluetooth connection to CPR-Feedbacksensor
- WiFi connection to Atlas Mannequin
For full functionality, access to the corpuls simulation COMMUNITY is required as well as a valid license.
more C3:
- Adjusting the jog dial button in defibrillator mode no longer causes a disconnection with the control iPad
- Alarm notifications now automatically close after accepting a new Autolimits setting, provided the current parameter value falls within the updated limit.
- SpO2 probe button now triggers a 'oxi sensor loose' alarm on the monitor
- After 15 seconds of RR dropping to zero, the apnoea alarm now appears while CO₂ value disappears
- QRS markers are removed from ASYNC mode and now only appear in SYNC mode
C1:
- Device can no longer be turned on by pressing the 'Defib' button
2.3.4 13 Mar
C1:
- Improved pacing menu including 'FIX' mode
- 'STIM' text now appears during pacing
- Updated AED and manual mode mode soft keys
- Updated sound files in AED and manual mode
- Metronome text status appears immediately in AED and manual mode
- Disconnected therapy electrodes from control iPad now recognised in defibrillator mode
- QRS tone remains on when switching between defibrillator and pacing mode
- Inverted screen is now coloured
C3:
- Improved pacing menu including 'FIX' mode
- Pacing in 'DEMAND' mode only possible with M-ECG
- QRS and pacer impulse markers now appear during pacing
- When stopwatch is activated, it will pause when the scenario is paused
- QRS tone remains on when changing from monitor to defibrillator mode
- First curve in defibrillator mode can no longer be changed from ECG
- 'Charge' and 'Analyse' keys now activate defibrillator mode from the monitor
- Defibrillator mode voice prompts are ceased when switching from defibrillator to pacer
Video debriefing:
- Red marker on timeline moves to correct place when an event is selected
- Improved stability
Other:
- The "+" button for increasing the pacer setting is now fully visible and selectable
- Improved DE translations on control iPad
- RR and ETCO2 values are pre-set at beginning of a scenario
- 'Escalation protocol' option removed from C1 and C3 monitor settings
2.3.3 05/12/2025
AED:
- Overlap up of DE voice prompts with activation of auto-analysis setting resolved
- Device will only perform a rhythm analysis when therapy electrodes are connected
C1:
- Double up of "press analyse" at the end of a 2 min CPR cycle resolved
- AED now performs an analysis of a non-shockable rhythm
- Dynamic pulse tone now present even without ECG rhythm on screen
- In manual defibrillator mode, Auto Sync, Sync and Async options are now in the correct order. Auto Sync. is now the default setting
- In defibrillator mode, small pie chart symbol changed to lightning symbol
- View options updated to be the same as default device settings
C3:
- When device is powered on using 'Manual' hard key, the 'Charge' hard key will work immediately
- Jog dial symbol added to relevant text in 2min CPR cycle
- VF/VT alarm now appears
- Translation error for "alarms suspended" resolved in DE
- Translation error for "Perform preShock CPR" resolved in DE
- Translation error for "Switch off pacer?" resolved in DE
- In AED, if a shock is left to disarm automatically, the pie chart restarts, and the user is prompted to recommence CPR
- Pie chart remains consistent and does not reset when changing between AED and manual mode
- Curves can now be changed on defibrillator screen
- Confirmation appears when changing from pacing to defibrillator
- Confirmation appears when pausing pacing therapy
- Metronome Autostart behaviour improved
General:
- When a scenario is paused on the control iPad, the monitor no longer continues to run in the background.
- Improved DE translations on control iPad
- Upon the first login to corpuls community, the new user is prompted to change their password
2.3.2 08/07/2025
- Improved C1 DE translations (All text now in DE)
- Replaced “QRS” text for soft key on C1 with “QRS/PT”
- Improved C3 DE translations (“pause alarms” and “measuring D-ECG” now in DE, not EN)
- Updated voice prompts and text within 2min CPR cycle in manual and AED mode on C3
- C3 2 min CPR cycle pie chart symbol updated to reflect C3 software version 4.4
- C3 “press analyse” prompt now present at the end of 2min cycle in AED mode
- C3 “connect therapy electrodes” text and voice prompt present if therapy electrodes are disconnected
- C3 soft key ‘cancel’ now present to disarm shock in AED mode
- C3 screen configurations made during the scenario will now remain the same when vital sign changes are made
- More accurate I:E ratio CO2 waveforms
2.3.1 27/02/2025
- Incorrect buttons (Energy, 100 and 200) no longer appear in AED on the corpuls3/corpuls3T
- Alarm limits are recognised and functional on the corpuls3/corpuls3T
2.2.12 25/11/2024
Bugfixes
corpuls 3/3T
- Fixed issue with metronome count not reverting to original configured ratio.
- Fixed issue with Start Analysis being played just after powering on, no delay.
- Fixed issue with metronome not resetting to Adult 30:2 when C3/CT is powered off.
2.2.11 29/10/2024
- Unclaimed generic monitor changed to corpuls3
- AED improvements
- Patient movement during analyse is detected in every device correctly
2.2.10 12/06/2024
corpuls3 / c3T:
- Metronome is now on when charging
- Improved power-off dialogue: If not confirmed, power-off dialog closes after 10s
- Fixed function of cancel button
- Invasive blood pressure: Add autoscaling for values > 180 mmHg
- Enabled cancel button after analyse button is pressed
corpuls1:
- Removed pleth waveform and replaced with CPR feedback in defib mode
- Removed alarm in AED mode
- Start mission timer during start
Staging App:
- Added additional oppurtunity to "Monitor" to open remotly open the "devices" menu on the monitor iPad
- Added "Voice of God" function to the "Sound" menu. To use this, use a wireless speaker connected via Bluetooth
2.2.9 06/06/2024
corpuls3/corpuls3T
- Bug fixed, that the shown curves cannot be changed in Pacer-Mode
corpuls1
- cpr feedback curve is now initially displayed in Defib.-Mode
2.2.7 23/05/2024
corpuls3:
- fixed overlapping time symbol and hour glass
- fixed position of power-off confirmation button
- fixed alarm behavior in defib.-mode
2.2.6 02/05/2024
AED Improvement:
- flashing analyse button
- CPR during analyse abort the analyse
2.2.4 09/04/2024
Bugfix in corpuls AED interface
2.2.3 27/03/2024
- PieChart fix
2.2.2 05/03/2024
- Fixed pie chart in Manual-Mode
2.2.1 04/03/2024
- In addition to showing and hiding the SpO2 curve, it is now also possible to select whether the sensor has been placed on the finger in the staging menu
- The connection menu for additional devices such as the CPR sensor band or the corpuls simulation Training Manikin has been redesigned
- The user can now select, if the metronome is initially switched off or on
- CPR-Feedback can now be switched from adult to children
- The alarm display on the click-dial-wheel has been improved and now flashes as long as the alarm is active
- Defib.-Patches are now preconnected
- Bugfix: The etCO2 alarm limits are now also given in mmHg instead of kPa
- Bugfix: If the c3T is started with the "Manual" button, the manual defibrillator starts now
- Bugfix: Display improvements in NIBP Menu
- Bugfix: The monitor view now shows the IBP curve instead of the CPR curve
- Bugfix: Improvement in the display of the ECG curve. If Defib.-Menu is started with the display initially not activated, the curve is now displayed after the display is activated
2.2.0 20/02/2024
- corpuls3 /C3T - automatic AED analysis
- Advanced settings for display configuration
- Introduction of auto alarm limits
- Bugfixes and improvements
2.1.1 28/08/2023
corpuls1
- Metronome-symbol and QRS-symbol don't show at the same time any more
- QRS-tone and metronome are disabled during AED-Rhythm analyse
- NIBP Sound and Metronome now work at the same time
- Blinking heart symbol improved
- Pie chart now available in AED an manual Defib.-Mode
corpuls3/corpuls3T
- Some translation errors fixed
- Pie chart now works without flicker
- Automatic switching off metronome after corpuls cpr is connected
- NIBP Sound and Metronome now work at the same time
- Curve selection in Defib.-Mode now works
2.1.0 23/06/2023
- Atlas Mannequin connection
- CPR-Feedbacksensor connectivity
- Video-Debriefing
- Bugfixes
1.1.0 29/03/2023
• Workflow improvement corpuls aed
• Additional corpuls aed versions
• Settings menu for corpuls aed
• Improvements NIBP measurement on corpuls3/corpuls3T
• Improvements alarm management on corpuls3/corpuls3T
• Several bug fixes
1.0.1 16/03/2021
C3:
- Adjusting the jog dial button in defibrillator mode no longer causes a disconnection with the control iPad
- Alarm notifications now automatically close after accepting a new Autolimits setting, provided the current parameter value falls within the updated limit.
- SpO2 probe button now triggers a 'oxi sensor loose' alarm on the monitor
- After 15 seconds of RR dropping to zero, the apnoea alarm now appears while CO₂ value disappears
- QRS markers are removed from ASYNC mode and now only appear in SYNC mode
C1:
- Device can no longer be turned on by pressing the 'Defib' button
more Version 2.3.4 13 Mar