ILYEO
Guided Red Light Therapy
Free · Designed for iPad. Not verified for macOS.
Meet the ILYEO body app, your companion for getting the most out of your ILYEO bodyPrecision Red-Light Therapy device.
ILYEO body is an FDA-registered Class II, 510(k)-exempt medical device indicated for the temporary relief of minor muscle and joint pain, arthritis pain and stiffness, and muscle spasms,and for the temporary increase of local blood circulation.
The ILYEO body app connects to your device over Bluetooth to guide every session, so you always know exactly where to place the pad, how long to treat, and how your relief is building over time.
WHAT YOU CAN DO IN THE APP
Personalized Treatment Protocols Set up guided protocols tailored to where you carry pain,whether it is your neck, shoulder, elbow, wrist and hand, lower back, hip, knee, ankle and foot,upper and mid back, or abdomen.
Guided Placement Instructions Step-by-step, in-app instructions help you position the flexible silicone pad correctly against the treatment area for a consistent, effective session every time.
Session Calendar and Reminders Keep your routine on track with a built-in session calendar and gentle reminders, so relief stays consistent rather than occasional.
Pain Tracking Log how you are feeling before and after sessions to see your own patterns and progress over time, right alongside your treatment history.
ABOUT YOUR ILYEO BODY DEVICE
ILYEO body pairs precision red light with thermal energy and gentle vibration in a single 10-minute session:
1.Precision Red Light: 662 nm ± 5 nm wavelength, delivered through 12 high-poweredLEDs directly to the treatment area, supporting cellular energy production.
2.Thermal Energy: soothing heat up to 43°C that complements the light therapy experience.
3.Gentle Vibration: adds comfort throughout each session.
Independently lab-tested output delivers up to 28 J/cm² of red-light energy in one 10-minute session, with average irradiance up to 47 mW/cm². ILYEO body is third-party tested to IEC medical electrical and photobiological safety standards, so what you get is real, measured, clinic-grade output, not a diluted broad-panel approach.
The device itself is cordless, rechargeable, and hands-free, with a medical-grade silicone pad that is free of latex, phthalates, and BPA, and an adjustable 57 cm strap so it stays in place while you go about your day, at your desk, in the car, or making dinner.
Download the free ILYEO body app to unlock guided sessions, track your relief, and get more from your device with every use.
This app is designed for use with the ILYEO body device, sold separately, and intended for use by adults 18 years of age and older.
bug fixes
The developer, Joylux Inc., indicated that the app’s privacy practices may include handling of data as described below. For more information, see the developer’s privacy policy .
Data Linked to You
The following data may be collected and linked to your identity:
- Contact Info
- Identifiers
- Diagnostics
- Other Data
Data Not Linked to You
The following data may be collected but it is not linked to your identity:
- Diagnostics
Accessibility
The developer has not yet indicated which accessibility features this app supports. Learn More
Information
- Seller
- Joylux, Inc.
- Size
- 53.2 MB
- Category
- Health & Fitness
- Compatibility
Requires iOS 15.6 or later.
- iPhone
Requires iOS 15.6 or later. - iPad
Requires iPadOS 15.6 or later. - iPod touch
Requires iOS 15.6 or later. - Mac
Requires macOS 12.5 or later and a Mac with Apple M1 chip or later. - Apple Vision
Requires visionOS 1.0 or later.
- iPhone
- Languages
- English
- Age Rating
16+
- 16+
- Frequent
Medical Treatment information
Contains
Health or Wellness Topics
- Medical Device
Yes
- Joylux Inc. indicated this app is a regulated medical device and complies with United States law.
- The information below has not been verified by Apple.
- FDA Owner/Operator Number
- 10087681
- Address
- 5628 Airport Way S Ste 210
Seattle Washington 98108
United States - Phone Number
- +970 592 051 039
- qasem@joylux.com
- Use Statement
- ILYEO body is an externally applied red light therapy device indicated for the temporary relief of minor muscle and joint pain, arthritis pain and stiffness, muscle spasms, and for the temporary increase of local blood circulation. The device is intended for home use by adults 18 years of age and older. ILYEO body is a Class II, 510(k) exempt medical device registered with the FDA.
- Safety Information
- Please read the following safeguards before using. Please use caution and good judgment when using the device.
• Use this product only for its intended use as described in these directions.
• This device is not intended for use by anyone under the age of 18, and close adult supervision is necessary if children under the age of 18 are near the device. Keep the USB charging cord away from children, as it poses a strangulation risk.
• WARNING: Water and electricity are a dangerous combination. To avoid risk of electrocution, the controller, power cord, and device should not be used in wet surroundings. Do not let water run into the device.
• WARNING: Do not leave the equipment unattended when it is switched on to avoid the risk of fire or burns.
• WARNING: This equipment is not intended for use by persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the equipment to avoid the risk of fire or burns.
• WARNING: This equipment is not intended for use by children. Children should be supervised to ensure that they do not play with the equipment to avoid the risk of fire and burns.
• CAUTION: Do not subject the equipment to heavy shocks to avoid risk of damage to the lamp.
• Only connect the device with the USB cable provided and to USB power adapters certified in compliance with IEC 60950-1 or IEC 60601-1 based national standards.
• Do not use the device if the lights have been damaged in any way.
• Do not attempt to disassemble, modify, service or conduct any maintenance on this device. Unforeseeable hazards may arise from modification of equipment.
• Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.
• Portable RF communications equipment that emit radio waves should be used no closer than 30 cm (12 inches) to any part of ILYEO body, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.
• Mobile RF communications equipment can affect medical electrical equipment.
• Do not use if you have autonomic neuropathy, sensory neuropathy, or pseudomotor dysfunction.
• WARNING: Can expose you to heavy metals, chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. See www.P65Warnings.ca.gov
• The device is designed for individual use only. Please do not share.
• After each use, the device should be thoroughly cleaned.
• Do not use the device if you are using cancer-fighting drugs, medications, or topical creams that increase photosensitivity. These may cause an adverse reaction.
• If you are experiencing prolonged redness or sensitivity in the treatment area, discontinue use and contact info@joylux.com.
• If the device begins to overheat, turn off immediately.
• If any part of the device is cracked, broken, or damaged or if there are signs of moisture or condensation on the inside of the device, discontinue use immediately.
• The PATIENT is an intended OPERATOR.
• Pad is BF type applied part.
• CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
• Do not use the device if you have impaired sensation in the treatment area, or have active skin cancer or suspicious lesions.
• Consult your healthcare provider before use if you are pregnant or have a history of skin cancer.
• This device is intended for external use only.
• Do not use on intimate tissues.
• Do not use on the face.
• Do not use silicone-based lubricants with the device.
• Do not stare directly into the device lights.
• If you experience numbness, skin irritation, dizziness, or feel pain, stop using this device immediately and consult your physician.
• Exercise caution when using near body piercings as the piercing may get hot when exposed to the heat.
- Instructions for Use
- Visit the developer site
- Copyright
- © 2021 Joylux, inc.
