Edan Nano

Nano ultrasound in your pocket

Free · Designed for iPad. Not verified for macOS.

The Nano application is designed to work with the Nano series probes, providing a portable and flexible ultrasound solution. Nano application offers various scanning modes and dedicated presets for different scenarios.To help support your workflow the app provides intuitive measurement and annotation tools right on your display device. Enjoy the flexibility of easily sharing exam images or clips with your DICOM® server or other apps, with just a few taps. *Not available in all countries. Disclaimer: Consult a physician before making any medical decisions based on Nano. Prior to use, carefully read the contraindications. Do not use the device if any contraindications apply. Edan Instruments, Inc. (hereinafter referred to as "Edan Instruments") shall not be liable for any consequences resulting from unauthorized or improper use.

  • This app hasn’t received enough ratings or reviews to display an overview.

The developer, EDAN Instruments, Inc., indicated that the app’s privacy practices may include handling of data as described below. For more information, see the developer’s privacy policy .

  • Data Not Linked to You

    The following data may be collected but it is not linked to your identity:

    • Health & Fitness
    • Contact Info

Privacy practices may vary, for example, based on the features you use or your age. Learn More

The developer has not yet indicated which accessibility features this app supports. Learn More

Seller
EDAN Instruments, Inc.
Size
312.6 MB
Category
Medical
Compatibility
Requires iOS 18.3.2 or later.
  • iPhone
    Requires iOS 18.3.2 or later.
  • iPad
    Requires iPadOS 18.3.2 or later.
  • Mac
    Requires macOS 15.4 or later and a Mac with Apple M1 chip or later.
  • Apple Vision
    Requires visionOS 2.4 or later.
Languages
English and 9 more
  • English, French, German, Italian, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Turkish
Age Rating
16+
Medical Device
Yes
  • EDAN Instruments, Inc. indicated this app is a regulated medical device and complies with United States law.
  • The information below has not been verified by Apple.
  • FDA Owner/Operator Number
  • 9055347
  • Address
  • China Mainland
    GUANGDONG
    Shenzhen
    No.15, Jinsha Shequ Jinhui Road,
    Kengzi Sub-District,Pingshan New District, Shenzhen
    518067
  • Phone Number
  • +86 188 1949 7874
  • Email
  • edanios@edan.com.cn
  • Use Statement
  • The Nano application from EDAN Instrument Inc. is designed to work with the Nano series probes,providing a portable and flexible ultrasound solution. This ultrasound solution enables a qualified physician or allied health professional to perform ultrasound scans whenever needed.
    Nano application offers various scanning modes and dedicated presets for different scenarios.To help support your workflow the app provides intuitive measurement and annotation tools right on your display device.
    Enjoy the flexibility of easily sharing exam images or clips with your DICOM® server or other apps, with just a few taps.
    *Not available in all countries.
  • Safety Information
  • 1.Warnings
    Use only EDAN‑supplied power adapter and accessories; non‑approved may cause incorrect results, safety issues or increased emissions or decreased immunity of the equipment.Do not use adapter in transport/emergency.
    Use the power adapter to isolate the probe from mains; position it for easy disconnection.
    The battery is non-removable.
    Nano is IP67 rated (dust-proof and against temporary immersion). Avoid prolonged moisture exposure; the connection cable is not splash‑proof and must be kept dry.
    Unplug charger when not charging to avoid energy waste and electrical risk.
    Operation exceeding specified physiological signal or the operational specification may cause inaccurate results.
    Avoid excessive temperature, humidity, dirt, direct sunlight, and wet environments (RH > 95%).
    Do not use the probe near heat sources or above 40˚C or store above 45˚C.Do not heat or dispose of in fire.
    Parts/accessories, and/or the system configuration,must meet IEC/EN60601 series safety standards.
    Clean and disinfect probes and reusable accessories after each exam using FDA-cleared protective barriers. Follow instructions, sterile procedures and infection control policies for personnel and equipment.
    Use single‑use sheath when performing biopsy.
    Latex-containing sheaths may cause severe allergy in sensitive persons. Healthcare professionals should identify latex-sensitive patients and be prepared to treat allergic reactions immediately. (Refer to March 29, 1991 Medical Alert on Latex products)
    Improper operation may cause battery overheating, ignition, or explosion. Read user manual and warnings carefully.
    Do not touch accessible contacts of electrical equipment and the patient simultaneously.
    Do not maintain system while in use with patient.
    Install the system according the EMC guidance provided in Appendix D
    Do not stack the system on other electronic equipment.
    See Appendix D for separation distances from other equipment, including portable and RF devices.
    In road ambulance environments, maintain minimum separation between multiple operating devices to prevent interference.
    No modification allowed.
    The system should be maintained annually by qualified technician.
    Keep non-medical equipment out of the vicinity of the patient. (1.5m/6ft.)
    Use sterile technique for biopsy; sterilize the needle guide between uses; use a sterile needle each time.
    Stop using if needle guide bracket or needle is bent, twisted, or deformed.
    Other equipment may interfere with the system even if CISPR EMISSION compliant.
    Do not use with high‑frequency surgical equipment.
    Follow manufacturer instructions for disinfectants.
    Ensure disinfectant has not expired.
    The Nano is not for intra-cardiac use or direct cardiac contact or contact with the central nervous system and central cardiovascular system.
    Disconnect the probe before cleaning or disinfecting.
    If the probe is not used for a long time, charge at least every 3 months to prevent over-discharge.
    Do not connect probe via cable when tablet/phone is on platform.
    2. Precautions
    Avoid dusty, vibrating environments and flammable anesthetics.
    Inspect equipment, cables, probes before use; replace if damaged.
    Follow ALARA: minimize ultrasound exposure time and power.
    The system generates radio frequency energy, which may interfere with nearby devices or cause image distortion; reposition if needed.
    Use only by qualified physicians or health professionals.
    System not for long-term storage; back up data regularly and confirm success before deletion.
    Confirm patient ID before storing or printing any exam information.
    Images may have artifacts; use only as part of overall clinical assessment.
    To avoid electrical shock, disconnect from AC power before cleaning.
    The system contains no user serviceable parts; repairs only by EDAN-certified personnel.
    Dispose of device, accessories, packaging, and cleaning agents per local/hospital regulations.
    Report serious incidents to manufacturer and competent authority.
    Automated cleaning/disinfection prohibited.
    2.1 Probe Cautions
    Do not use disinfection agents or sterile sheaths beyond expiration.
    Inspect Type-C cable and probe periodically; do not use if worn or damaged.
    Do not use probe emitting excessive heat or malfunctioning to avoid tissue damage.
    Do not kink or pull on the USB cable.
    When using the probe in home, place cables to avoid strangulation and store probe away from pets, children, and pests.
    Avoid using across significant pressure differences to prevent button malfunction.
    3. Contra-indications
    The Nano Series Diagnostic Ultrasound System is not intended for ophthalmic use or any use causing the acoustic beam to pass through the eye.
    4. Adverse Event Reporting
    To report a problem or adverse event to the FDA, visit www.fda.gov/safety/report-problem-fda
  • Instructions for Use
  • Visit the developer site
Copyright